• J. Thorac. Cardiovasc. Surg. · Jan 1999

    Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure.

    • O Kawaguchi, W E Pae, B B Daily, and W S Pierce.
    • Department of Surgery, Division of Cardiothoracic Surgery, College of Medicine, The Pennsylvania State University, The Milton S. Hershey Medical Center, Hershey, PA 17033, USA.
    • J. Thorac. Cardiovasc. Surg. 1999 Jan 1; 117 (1): 164-71.

    PurposeWe analyzed the mechanism of effects of intra-aortic balloon pumping using the pressure-volume relationship and ventriculoarterial coupling in the normal and failing hearts.MaterialsIn 12 anesthetized Holstein calves (weight, 94 +/- 8 kg), the ventricular end-systolic and arterial elastances, pressure-volume area, and external work were analyzed during steady-state contractions with traditional hemodynamic parameters with intra-aortic balloon pumping-off and -on (1:1 synchronous ratio). An acute ischemic heart failure was induced by injecting 10 microm microspheres (4.2 +/- 1.8 x 10(7). 100g left ventricular weight-1) into the left main coronary artery; all measurements were repeated.ResultsIntra-aortic balloon pumping did not change hemodynamic parameters in the control. However, during heart failure, intra-aortic balloon pumping decreased the arterial elastance from 3.6 +/- 1.3 mm Hg to 2.9 +/- 1.2 mm Hg. mL-1 while not affecting the ventricular end-systolic elastance, this resulted in an improvement of the ventriculoarterial coupling ratio from 3.1 +/- 0.8 to 2.3 +/- 0.8. Intra-aortic balloon pumping decreased not only end-systolic pressure (from 69 +/- 16 mm Hg to 64 +/- 19 mm Hg) but end-diastolic volume and pressure (from 139 +/- 38 mL to 137 +/- 37 mL and from 13. 9 mm Hg to 12.8 mm Hg, respectively) with the leftward shift of the pressure-volume loop. Pressure-volume area decreased (from 914 +/- 284 mm Hg to 849 +/- 278 mm Hg. mL) although stroke volume increased (from 21 +/- 6 mL to 24 +/- 6 mL).ConclusionReduction of the arterial elastance with intra-aortic balloon pumping improved the ventriculoarterial coupling ratio and increased stroke volume. Leftward shift of the pressure-volume loop resulted in the reduction of pressure-volume area, which suggests the conservation of the myocardial oxygen consumption.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.