• J. Thorac. Cardiovasc. Surg. · Aug 2000

    Maximizing hemodynamic effectiveness of biventricular assistance by direct cardiac compression studied in ex vivo and in vivo canine models of acute heart failure.

    • J H Artrip, G H Yi, J Shimizo, E Feihn, R R Sciacca, J Wang, and D Burkhoff.
    • Department of Surgery, Division of Cardiothoracic Surgery, College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
    • J. Thorac. Cardiovasc. Surg. 2000 Aug 1; 120 (2): 379-86.

    ObjectiveDirect cardiac compression improves effective ventricular contractility. However, associated reductions in filling volumes and increases in arterial pressure occurring at the onset of direct cardiac compression limit the degree to which cardiac output is augmented. We tested the hypothesis that active preload and afterload control maximizes the hemodynamic effectiveness of direct cardiac compression.Methods And ResultsStudies in isolated canine hearts loaded with a computer-controlled volume servo system that mimicked heart failure were used to clearly define the hemodynamic effects of direct cardiac compression. Immediately on initiation of direct cardiac compression, ventricular end-diastolic pressure and volume decreased substantially, arterial pressure increased, but stroke volume did not change significantly. When end-diastolic pressure was restored to about 20 mm Hg, stroke volume doubled; decreasing afterload resistance further increased stroke volume by about 30%. Such load adjustments were then tested in vivo in a canine model of acute heart failure induced by coronary artery microembolizations titrated to decrease cardiac output to 33% +/- 9% of control as end-diastolic pressure rose to 20.6 +/- 2.2 mm Hg. Direct cardiac compression decreased end-diastolic pressure to 11.4 +/- 2.6 mm Hg while increasing cardiac output from 0.8 +/- 0.2 to 1. 4 +/- 0.5 L/min (to only approximately 55% of normal). Restoring end-diastolic pressure to 19.6 +/- 2.2 mm Hg by infusions of saline solution increased cardiac output to 1.9 +/- 0.5 L/min. Afterload reduction (nitroprusside), while maintaining end-diastolic pressure at 19.8 +/- 1.3 mm Hg, increased cardiac output to its baseline, 2.8 +/- 1.1 L/min.ConclusionsDirect cardiac compression significantly improves ventricular pumping capacity and can restore cardiac output to about 60% of normal in the setting of acute heart failure. When combined with active preload and afterload manipulations, direct cardiac compression can restore cardiac output to normal.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…