• Journal of neurosurgery · Apr 2017

    Efficacy of a coaxial system with a compliant balloon catheter for navigation of the Penumbra reperfusion catheter in tortuous arteries: technique and case experience.

    • Kazuki Takahira, Taketo Kataoka, Tatsuya Ogino, Hideki Endo, and Hirohiko Nakamura.
    • Department of Neurosurgery, Center for Endovascular Neurosurgery, Nakamura Memorial Hospital, Sapporo; and.
    • J. Neurosurg. 2017 Apr 1; 126 (4): 1334-1338.

    AbstractOBJECTIVE The authors describe a method by which they easily and atraumatically navigate a large-bore reperfusion catheter of the Penumbra system to an embolus by using a coaxial system with a compliant balloon catheter in patients with tortuous arteries. METHODS A retrospective review of the prospective endovascular database was performed to identify cases in which a coaxial system with a compliant balloon catheter (Scepter C, MicroVention/Terumo; or TransForm C, Stryker Neurovascular) and a large-bore reperfusion catheter of the Penumbra system (Penumbra, Inc.) was used. The authors achieved a stable guiding sheath position and delivered the coaxial system with a compliant balloon catheter and a large-bore reperfusion catheter. Then, the balloon was inflated somewhat when the distal tip of the balloon was slightly advanced from the tip of the reperfusion catheter, and together the coaxial system was advanced to an embolus over a 0.014-in guidewire, even around the corner. When the distal tip of the balloon catheter reached the embolus, the authors deflated the balloon and navigated the large-bore reperfusion catheter to the embolus. Finally, the aspiration of the embolus with the Penumbra MAX pump was begun. RESULTS Between May 2014 and September 2015, the authors used this technique in 17 cases: 16 cases of middle cerebral artery occlusion (including 5 cases of internal carotid artery occlusion) and 1 case of basilar artery occlusion (age range 36-88 years, mean age 74.7 years, 13 men). For the reperfusion catheter of the Penumbra system, the 5MAX ACE was used in 15 cases, and the 5MAX was used in 2 cases. As a compliant balloon catheter, the Scepter C was used in 16 cases, and the TransForm C was used in 1 case. The technique was successful in 16 cases (94.1%). No parent artery dissections were noted in any cases. Catheter-induced vasospasm was noted in 1 case, but the vasospasm was transient. CONCLUSIONS A coaxial system with a compliant balloon catheter can help safely and easily to navigate the large-bore reperfusion catheter of the Penumbra system to an embolus in patients with tortuous arteries.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…