• Hemodial Int · Oct 2010

    Reproducibility of regional pulse-wave velocity in uremic subjects.

    • Biagio R Di Iorio, Emanuele Cucciniello, Pietro Alinei, and Serena Torraca.
    • UO Nefrologia, PO A. Landolfi, Solofra (AV), Italy. br.diiorio@gmail.com
    • Hemodial Int. 2010 Oct 1; 14 (4): 441-6.

    AbstractDespite the clinical importance of pulse-wave velocity (PWV), there are no standards for accurate carotid-radial pulse-wave measurement in uremic patients with respect to carotid-femoral measurement. We assessed the reproducibility of PWV values using the carotid-radial PWV measurement. We have measured the carotid-femoral PWV and carotid-radial PWV with an automated system (Pulse Pen, DiaTecne) using 2 different blind operators in 105 hemodialysis (HD) patients. The carotid-femoral waveforms were acquired by the first blind operator simultaneously with 2 pressure-sensitive transducers and the transit time of the pulse was calculated using the system software. Similarly, the second blind operator acquired the carotid-radial waveforms. The two operators performed 2 consecutive measurements from the same subject, in a random order. In fact, after the first operator had completed 2 consecutive measurements from 1 subject, all of the sensors were detached, and the second operator attached sensors again to the same subject. The measurements were performed during interval of a midweek dialysis-free day. To evaluate the reproducibility of the system, both within-observer and between-observer analyses were performed. We studied 105 dialysis patients (HD) and 20 controls. All HD patients had three dialysis sessions lasting at least 4 h/wk. A total of 28 patients (26.7%) had diabetic nephropathy. The mean age of HD was 64.6 ± 16.1 years, the body weight was 71.1 ± 15.1 kg, and the height was 164.6 ± 6.1 cm. All population studied is referral at a tertiary care from at least 6 months (mean 11.1 ± 2.1 months). A total of 45% of patients are smokers or ex-smokers. The PWV of carotid-femoral is 8.58 ± 3.99 and the PWV of carotid-radial is 8.70 ± 4.01 m/sec, respectively, by the first and the second operator; the difference of PWV (femoral-radial measure) is -0.037 ± 0.99 m/sec. The linear correlation of carotid-femoral vs. carotid-radial PWV measurements is the highest (R(2) =0.90). The results regarding reproducibility, including mean differences and standard deviations, standard errors, and correlation coefficients were analyzed for each regional PWV value for the between-observer and within-observer studies. All of the measurements showed significant correlation coefficients, ranging from 0.94 to 0.98. The reproducibility of regional PWV values for 2 consecutive measurements from the same subject was also analyzed using Bland-Altman plots, with the reproducibility expressed as the mean difference and 2 standard deviations between the measurements obtained by the 2 operators during carotid-femoral and carotid-radial measurements. Carotid-radial PWV measurement provides an accurate analysis with a high reproducibility with respect to carotid-femoral PWV measurement, and it can be used for arterial stiffness analysis in hemodialysis patients.© 2010 The Authors. Hemodialysis International © 2010 International Society for Hemodialysis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,706,642 articles already indexed!

We guarantee your privacy. Your email address will not be shared.