• European heart journal · Jul 2009

    Comparative Study

    Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI.

    • Hans-Joachim Nesser, Victor Mor-Avi, Willem Gorissen, Lynn Weinert, Regina Steringer-Mascherbauer, Johannes Niel, Lissa Sugeng, and Roberto M Lang.
    • Public Hospital Elisabethinen, Linz, Austria.
    • Eur. Heart J. 2009 Jul 1; 30 (13): 1565-73.

    AimsAlthough the utility of two-dimensional (2D) speckle tracking echocardiography (STE) to quantify left ventricular (LV) volume has been demonstrated, this methodology is limited by foreshortened views, geometric modelling, and the assumption that speckles can be tracked from frame to frame, despite their out of plane motion. To circumvent these limitations, a three-dimensional (3D) speckle tracking algorithm was recently developed. Our goal was to evaluate the accuracy of the new 3D-STE side by side with 2D-STE using cardiac magnetic resonance (CMR) as a reference.Methods And ResultsApical two- and four-chamber views (A2C and A4C) and real-time 3D datasets (Toshiba Artida 4D System) obtained in 43 patients with a wide range of LV size and function were analysed to measure LV end-systolic and end-diastolic volumes (ESV and EDV) using 2D and 3D-STE techniques. Short-axis CMR images (Siemens 1.5T scanner) acquired on the same day were analysed to obtain ESV and EDV reference values using the method of disks approximation. Reproducibility of both STE techniques was assessed using repeated measurements. While 2D-STE correlated well with CMR (r: 0.72-0.88), it underestimated LV volumes with relatively large biases (10-30 mL) and wide limits of agreement (SD: 36-51 mL), with A2C-derived measurements being worse than A4C values. The 3D-STE measurements showed higher correlation with CMR (0.87-0.92), and importantly smaller biases (1-16 mL) and narrower limits of agreement (SD: 28-37 mL). In addition, 3D-STE showed lower inter- and intra-observer variability (11-14% and 12-13%), than 2D-STE (16-17% and 12-16%, respectively).ConclusionThis is the first study to validate the new 3D-STE technique for LV volume measurements and demonstrate its superior accuracy and reproducibility over previously used 2D-STE technique.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…