• J. Thorac. Cardiovasc. Surg. · Aug 2008

    Randomized Controlled Trial Comparative Study

    A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning?

    • Ralf Guenzinger, Walter Benno Eichinger, Ina Hettich, Sabine Bleiziffer, Daniel Ruzicka, Robert Bauernschmitt, and Ruediger Lange.
    • Department of Cardiovascular Surgery, German Heart Center Munich, Technical University of Munich, Munich, Germany. guenzinger@dhm.mhn.de
    • J. Thorac. Cardiovasc. Surg. 2008 Aug 1; 136 (2): 462-71.

    ObjectiveThe aim of this prospective randomized trial was to evaluate the impact of complete supraannular positioning of mechanical aortic bileaflet valves.MethodsBetween April of 2004 and November of 2006, 80 patients underwent aortic valve replacement with the complete supraannular Medtronic Advantage Supra (n = 40) (Medtronic Inc, Minneapolis, Minn) or the intra-supraannular St Jude Medical Regent (n = 40) prosthesis (St Jude Medical Inc, St Paul, Minn). Before randomization and valve sizing for both valve types, the aortic tissue annulus diameter was determined by Hegar dilator. Transthoracic echocardiography data were obtained early postoperatively and at 6 months, including stress echocardiography.ResultsBy grouping the data on the basis of a patient's tissue annulus diameter, no significant difference of either valve was detected with regard to mean pressure gradient and effective orifice area index at rest. Effective orifice area index ranged from 0.95 +/- 0.32 cm(2)/m(2) to 1.27 +/- 0.33 cm(2)/m(2) in the Advantage Supra group and from 0.98 +/- 0.36 cm(2)/m(2) to 1.26 +/- 0.37 cm(2)/m(2) in the Regent group. During exercise, mean pressure gradients increased from 11.9 +/- 4.9 mm Hg to 19.1 +/- 7.2 mm Hg in the Advantage Supra group and from 9.6 +/- 4.0 to 16.4 mm Hg +/- 7.3 mm Hg in the Regent group. A marked left ventricular mass regression across all annulus sizes was noted in both groups (P < .001). Sizing for both valve types showed that in 26.3%, the completely supraannular valve design allows the implantation of a 1 size larger valve in label than the corresponding intra-supraannular valve.ConclusionBy grouping the data on the basis of a patient's tissue annulus diameter, no significant superiority of either prosthesis was detected with regard to left ventricular mass regression, effective orifice area index, and mean pressure gradient during rest and exercise. We conclude that there is no additional benefit of supraannular valve positioning.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.