• Clin J Pain · Jan 2017

    Using a Standardized Clinical Quantitative Sensory Testing Battery to Judge the Clinical Relevance of Sensory Differences between Adjacent Body Areas.

    • Violeta Dimova, Bruno G Oertel, and Jörn Lötsch.
    • *Institute of Clinical Pharmacology, Goethe-University †Department of Anesthesiology, Intensive Care Medicine and Pain Therapy, University Hospital Frankfurt ‡Fraunhofer Institute for Molecular Biology and Applied Ecology IME, Project Group Translational Medicine and Pharmacology TMP, Frankfurt am Main, Germany.
    • Clin J Pain. 2017 Jan 1; 33 (1): 37-43.

    BackgroundSkin sensitivity to sensory stimuli varies among different body areas. A standardized clinical quantitative sensory testing (QST) battery, established for the diagnosis of neuropathic pain, was used to assess whether the magnitude of differences between test sites reaches clinical significance.MethodsTen different sensory QST measures derived from thermal and mechanical stimuli were obtained from 21 healthy volunteers (10 men) and used to create somatosensory profiles bilateral from the dorsum of the hands (the standard area for the assessment of normative values for the upper extremities as proposed by the German Research Network on Neuropathic Pain) and bilateral at volar forearms as a neighboring nonstandard area. The parameters obtained were statistically compared between test sites.ResultsThree of the 10 QST parameters differed significantly with respect to the "body area," that is, warmth detection, thermal sensory limen, and mechanical pain thresholds. After z-transformation and interpretation according to the QST battery's standard instructions, 22 abnormal values were obtained at the hand. Applying the same procedure to parameters assessed at the nonstandard site forearm, that is, z-transforming them to the reference values for the hand, 24 measurements values emerged as abnormal, which was not significantly different compared with the hand (P=0.4185).ConclusionsSensory differences between neighboring body areas are statistically significant, reproducing prior knowledge. This has to be considered in scientific assessments where a small variation of the tested body areas may not be an option. However, the magnitude of these differences was below the difference in sensory parameters that is judged as abnormal, indicating a robustness of the QST instrument against protocol deviations with respect to the test area when using the method of comparison with a 95 % confidence interval of a reference dataset.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…