• Can J Anaesth · Jan 1998

    Comparative Study

    Monitoring of pH and PCO2 in children using the Paratrend 7 in a peripheral vein.

    • J D Tobias, D J Meyer, and M A Helikson.
    • Department of Child Health, University of Missouri, Columbia 65212, USA.
    • Can J Anaesth. 1998 Jan 1; 45 (1): 81-3.

    PurposeTo determine the accuracy of the Paratrend 7 monitor inserted into a peripheral vein in providing continuous measurements of PCO2 and pH in children with respiratory failure.MethodsIn a prospective, case series at a University based PICU in a tertiary referral hospital and following informed consent, the Paratrend 7 intra-arterial blood gas monitoring system was inserted through a peripheral intravenous cannula. When clinically indicated, an arterial blood gas (ABG) was obtained. The values of pH and PCO2 from the Paratrend 7 and the ABG were compared using linear regression analysis and Bland-Altman analysis.ResultsSeventeen ABGs were obtained in the 4 patients. PaCO2 ranged from 29 to 51 mmHg and the pH values from 7.16 to 7.50. Linear regression analysis for the: Paratrend 7 pH vs the ABG pH resulted in an r = 0.9678 and an r2 = 0.9367 (P < 0.0001). Linear regression analysis for the Paratrend 7 CO2 vs ABG CO2 resulted in an r = 0.8273 and an r2 = 0.6845 (P = 0.01). Using a Bland and Altman analysis, the bias +/- precision of the PCO2 values was 3 +/- 1.4 and 0.036 +/- 0.02 for the pH values.ConclusionThe pH and PCO2 values obtained from the Paratrend 7 monitor provide a clinically acceptable correlation with arterial values.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…