• Lancet · Oct 2016

    Evaluation of absorbable composite polylactide-hydroxyapatite bone fixation devices: a cohort study.

    • Jianxun Ding, Xiuli Zhuang, and Xuesi Chen.
    • Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China. Electronic address: jxding@ciac.ac.cn.
    • Lancet. 2016 Oct 1; 388 Suppl 1: S30.

    BackgroundAt present, most bone fixation devices are made of metal, and are applied to prevent the postoperative dislocation of bone fragments. The major issues with such metal bone fixation devices are the necessity for secondary surgery to remove the devices, stress shielding of bone, stimulation and erosion of bone and soft tissue, and limited biocompatibility. To mitigate these problems, we aimed to assess use of a flexible absorbable polymer bone fixation devices. These devices were certified for use in China in September, 2015.MethodsIn this study, patients were treated at the First Hospital of Jilin University with absorbable fixation screws for fixation of non-weight-bearing bones (eg, metacarpal, phalange, talus, metatarsus, or inner ankle) or absorbable bone plates (eg, for hand, feet, ulna, or fibula fixation). Absorbable bone fixation devices were made from 90% by weight polylactide and 10% hydroxyapatite. Patients were followed up for at least 6 months, and evaluated clinically and radiographically at 3 months and 6 months after surgery. The ethics committee of the First Hospital of Jilin University gave ethical approval for the study and all patients provided written informed consent.FindingsBetween February, 2011, and July, 2014, 45 patients (62 screws; 33 men, 12 women; mean age 41·7 years [range 19-63; SD 12·5]) had absorbable fixation screws implanted and 45 patients (45 bone plates; 35 men, ten women; mean age 39·2 years [range 24-60; SD 10·4]) had absorbable bone plates. The flexural strength of the tested bone screw was ≥170 MPa and flexural modulus was ≥4000 MPa, and those of bone plate were ≥100MPa and ≥3000 MPa. The high mechanical properties met the requirements of clinical applications. No patients required revision surgery, and no device-related adverse events were observed during the 6 month follow-up period. 6 months after implantation, the fracture healing rates were both 100% for both absorbable bone fixation screw and plate.InterpretationAbsorbable polylactide-hydroxyapatite bone fixation screws and plates seemed safe and effective in this study.FundingNational Natural Science Foundation of China (grants 51303174, 51473165, and 51390484).Copyright © 2016 Elsevier Ltd. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…