• Anaesth Intensive Care · Mar 2017

    Randomized Controlled Trial Comparative Study

    Ambu® AuraGain™ versus LMA Supreme™ Second Seal™: a randomised controlled trial comparing oropharyngeal leak pressures and gastric drain functionality in spontaneously breathing patients.

    • I I Shariffuddin, W H Teoh, Ebk Tang, Nhm Hashim, and P S Loh.
    • Associate Professor, Department of Anaesthesia, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
    • Anaesth Intensive Care. 2017 Mar 1; 45 (2): 244-250.

    AbstractNewer second generation supraglottic airway devices may perform differently in vivo due to material and design modifications. We compared performance characteristics of the Ambu® AuraGain™ and LMA Supreme™ Second Seal™ in 100 spontaneously breathing anaesthetised patients in this randomised controlled study. We studied oropharyngeal leak pressures (OLP) (primary outcome) and secondarily, ease of insertion, success rates, haemodynamic response, time to insertion, and complications of usage. We found no significant difference in OLP between the AuraGain versus the LMA Supreme, mean (standard deviation, SD) 24.1 (7.4) versus 23.6 (6.2) cmH2O, P=0.720. First-attempt placement rates of the AuraGain were comparable to the LMA Supreme, 43/50 (86%) versus 39/50 (78%), P=0.906, with an overall 98% insertion success rate for the AuraGain and 88% for the LMA Supreme after three attempts, P=0.112. However, the AuraGain was deemed subjectively harder to insert, with only 24/50 (48%) versus 37/50 (74%) of AuraGain insertions being scored 1 = easy (on a 5 point scale), P=0.013, and also took longer to insert, 33.4 (SD 10.9) versus 27.3 (SD 11.4) seconds, P=0.010. The AuraGain needed a smaller volume of air (16.4 [SD 6.8] versus 23.0 [SD 7.4] ml, P <0.001) to attain intracuff pressures of 60 cmH2O, facilitated more successful gastric tube insertion (100% versus 90.9%, P=0.046), and had significantly decreased sore throat incidence (10% versus 38%, P=0.020). One AuraGain and six LMA Supremes failed to be placed within the stipulated 120 seconds trial definition of 'success'; these patients had risk factors for failed supraglottic insertion. In conclusion, both devices had similar OLPs and performed satisfactorily. However, the AuraGain resulted in less postoperative sore throat despite being harder to and taking longer to, insert.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…