    ImportanceThe choice between bioprosthetic and mechanical aortic valve replacement in younger patients is controversial because long-term survival and major morbidity are poorly characterized.ObjectiveTo quantify survival and major morbidity in patients aged 50 to 69 years undergoing aortic valve replacement.Design, Setting, And ParticipantsRetrospective cohort analysis of 4253 patients aged 50 to 69 years who underwent primary isolated aortic valve replacement using bioprosthetic vs mechanical valves in New York State from 1997 through 2004, identified using the Statewide Planning and Research Cooperative System. Median follow-up time was 10.8 years (range, 0 to 16.9 years); the last follow-up date for mortality was November 30, 2013. Propensity matching yielded 1001 patient pairs.Main Outcomes And MeasuresPrimary outcome was all-cause mortality; secondary outcomes were stroke, reoperation, and major bleeding.ResultsNo differences in survival or stroke rates were observed in patients with bioprosthetic compared with mechanical valves. Actuarial 15-year survival was 60.6% (95% CI, 56.3%-64.9%) in the bioprosthesis group compared with 62.1% (95% CI, 58.2%-66.0%) in the mechanical prosthesis group (hazard ratio, 0.97 [95% CI, 0.83-1.14]). The 15-year cumulative incidence of stroke was 7.7% (95% CI, 5.7%-9.7%) in the bioprosthesis group and 8.6% (95% CI, 6.2%-11.0%) in the mechanical prosthesis group (hazard ratio, 1.04 [95% CI, 0.75-1.43). The 15-year cumulative incidence of reoperation was higher in the bioprosthesis group (12.1% [95% CI, 8.8%-15.4%] vs 6.9% [95% CI, 4.2%-9.6%]; hazard ratio, 0.52 [95% CI, 0.36-0.75]). The 15-year cumulative incidence of major bleeding was higher in the mechanical prosthesis group (13.0% [95% CI, 9.9%-16.1%] vs 6.6% [95% CI, 4.8%-8.4%]; hazard ratio, 1.75 [95% CI, 1.27-2.43]). The 30-day mortality rate was 18.7% after stroke, 9.0% after reoperation, and 13.2% after major bleeding.Conclusions And RelevanceAmong propensity-matched patients aged 50 to 69 years who underwent aortic valve replacement with bioprosthetic compared with mechanical valves, there was no significant difference in 15-year survival or stroke. Patients in the bioprosthetic valve group had a greater likelihood of reoperation but a lower likelihood of major bleeding. These findings suggest that bioprosthetic valves may be a reasonable choice in patients aged 50 to 69 years.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.