• N. Engl. J. Med. · Sep 2008

    Randomized Controlled Trial Multicenter Study

    Prognostic importance of defibrillator shocks in patients with heart failure.

    • Jeanne E Poole, George W Johnson, Anne S Hellkamp, Jill Anderson, David J Callans, Merritt H Raitt, Ramakota K Reddy, Francis E Marchlinski, Raymond Yee, Thomas Guarnieri, Mario Talajic, David J Wilber, Daniel P Fishbein, Douglas L Packer, Daniel B Mark, Kerry L Lee, and Gust H Bardy.
    • Division of Cardiology, University of Washington School of Medicine, 1959 NE Pacific St., Box 356422, Seattle, WA 98195-6422, USA. jpoole@u.washington.edu
    • N. Engl. J. Med. 2008 Sep 4; 359 (10): 1009-17.

    BackgroundPatients with heart failure who receive an implantable cardioverter-defibrillator (ICD) for primary prevention (i.e., prevention of a first life-threatening arrhythmic event) may later receive therapeutic shocks from the ICD. Information about long-term prognosis after ICD therapy in such patients is limited.MethodsOf 829 patients with heart failure who were randomly assigned to ICD therapy, we implanted the ICD in 811. ICD shocks that followed the onset of ventricular tachycardia or ventricular fibrillation were considered to be appropriate. All other ICD shocks were considered to be inappropriate.ResultsOver a median follow-up period of 45.5 months, 269 patients (33.2%) received at least one ICD shock, with 128 patients receiving only appropriate shocks, 87 receiving only inappropriate shocks, and 54 receiving both types of shock. In a Cox proportional-hazards model adjusted for baseline prognostic factors, an appropriate ICD shock, as compared with no appropriate shock, was associated with a significant increase in the subsequent risk of death from all causes (hazard ratio, 5.68; 95% confidence interval [CI], 3.97 to 8.12; P<0.001). An inappropriate ICD shock, as compared with no inappropriate shock, was also associated with a significant increase in the risk of death (hazard ratio, 1.98; 95% CI, 1.29 to 3.05; P=0.002). For patients who survived longer than 24 hours after an appropriate ICD shock, the risk of death remained elevated (hazard ratio, 2.99; 95% CI, 2.04 to 4.37; P<0.001). The most common cause of death among patients who received any ICD shock was progressive heart failure.ConclusionsAmong patients with heart failure in whom an ICD is implanted for primary prevention, those who receive shocks for any arrhythmia have a substantially higher risk of death than similar patients who do not receive such shocks.2008 Massachusetts Medical Society

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…