  • Circulation · Mar 2000

    Comparative Study

    Ventricular defibrillation with triphasic waveforms.

    • J Huang, B H KenKnight, D L Rollins, W M Smith, and R E Ideker.
    • Cardiac Rhythm Management Laboratory, Division of Cardiovascular Diseases, Department of Medicine, Department of Physiology, and Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, USA.
    • Circulation. 2000 Mar 21; 101 (11): 1324-8.

    BackgroundIt has been reported that triphasic defibrillation waveforms cause less myocardial injury than biphasic waveforms. This study compared the defibrillation thresholds (DFTs) of triphasic and biphasic waveforms.Methods And Results++DFTs were determined for a transvenous lead system and a 300-microF-capacitor defibrillator. In 8 pigs (group 1), DFTs were determined for 5 triphasic waveforms with tilts of 80%, 83%, and 86% and for 1 biphasic waveform. DFTs were determined in another 8 pigs (group 2) for 2 triphasic and 4 biphasic waveforms with tilts of 43%, 49%, and 56%. In both groups, a biphasic waveform from a 140-microF-capacitor defibrillator was also evaluated, and both shock polarities were tested for each waveform. In group 1, with the 300-microF-capacitor defibrillator, the leading-edge voltage and energy stored at DFT were significantly lower for triphasic waveforms with phase-duration ratios of 50/33/17 and an anode at the right ventricular electrode for phase 1 than for biphasic waveforms (P<0.001). In group 2, the stored energy of triphasic waveforms with 56% and 49% tilt was significantly lower than that of biphasic waveforms with the same tilts for anodal but not cathodal phase 1 at the right ventricular electrode. Electrode polarity significantly affected the DFT of triphasic waveforms for both studies.ConclusionsSome 80% tilt triphasic waveforms defibrillate more efficiently than biphasic waveforms with a 300-microF-capacitor defibrillator. The triphasic waveforms for both groups were not superior to 140-microF-capacitor biphasic waveforms. The efficacy of triphasic waveforms depends on phase durations and electrode polarity.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…