• BMC anesthesiology · Nov 2017

    Clinical Trial Observational Study

    The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study.

    • Haixia Wang, Xue Gao, Wei Wei, Huihui Miao, Hua Meng, and Ming Tian.
    • Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
    • BMC Anesthesiol. 2017 Nov 28; 17 (1): 156.

    BackgroundAirway management of the obese patient presenting for surgery is more likely to be a challenging problem. Supraglottic airway device has been adopted as a bridge to connect ventilation and tracheal intubation in obese patients who would be suffered with difficult intubation. The optimum sevoflurane concentration for supraglottic airway device insertion allowing spontaneous breathing in 50% of obese patients (ED50) is not known. The purpose of this study was to determine the ED50 of sevoflurane for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients requiring general anesthesia.MethodsThirty elective obese patients (body mass index 30-50 kg/m2) undergoing bariatric surgery were recruited in this study. The predetermined target sevoflurane concentration (initiating at 2.5% with 0.5% as a step size) was sustained for >5 min using a modified Dixon's up-and-down method, and then the supraglottic airway device Blockbuster™ was inserted. The patient's response to supraglottic airway device insertion was classified as either 'movement' or 'no-movement'. The ED50 of sevoflurane were determined by calculating the midpoint concentration of crossover point from 'movement' or 'no-movement' response.ResultsThe ED50 of sevoflurane for supraglottic airway device Blockbuster™ insertion in obese patients calculated using up-and-down method were 2.50 ± 0.60%. The ED50 and ED95 (95% confidence interval) obtained by probit regression analysis were 2.35 (1.28-3.42) % and 4.03 (3.16-17.83) % for supraglottic airway device Blockbuster™ insertion, respectively.ConclusionWe conclude that the optimum end-tidal sevoflurane concentration required for the supraglottic airway device Blockbuster™ insertion allowing spontaneous breathing in 50% of obese patients (ED50) is 2.5 ± 0.6%.Trial RegistrationChinese Clinical Trial Registry, ChiCTR-IPR-16009071 , Registered on 24 August 2016.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.