• Respiratory care · Sep 2018

    Editorial Comparative Study

    A Comparative Analysis of Ideal Body Weight Methods for Pediatric Mechanical Ventilation.

    • Jeffrey R Bilharz, Craig R Wheeler, Brian K Walsh, and Craig D Smallwood.
    • Department of Respiratory Care, Boston Children's Hospital, Boston, Massachusetts.
    • Respir Care. 2018 Sep 1; 63 (9): 1079-1084.

    BackgroundA universal method for determining ideal body weight (IBW) for the application of appropriate tidal volumes in children on mechanical ventilation is elusive. We sought to compare 3 commonly used IBW methods for subjects between ages 2 and 20 y.MethodsDemographic data were recorded, and the IBW was calculated based on the McLaren-Read, Moore, and body mass index methods by using growth chart data from the Centers for Disease Control and Prevention. The percentage error between each IBW method and the actual body weight were calculated and reported as median (interquartile range). We decided a priori that a ≥10% difference between the actual body weight and IBW would be clinically important. The Wilcoxon signed-rank test was used to compare the actual body weight with the IBW. Bland-Altman analysis was used to assess the individual agreement of each IBW method with the actual body weight. The Kruskal-Wallis test was used to detect differences among the IBW methods.ResultsA total of 58 subjects (36% female) were analyzed. The median (interquartile range) percent weight error between the actual body weight and calculated the IBW was 14.8% (1.9-22.1%, P = .038), 13.8% (4.6-23.4%, P = .008), and 12.0% (3.9-20.5%, P = .037); the mean biases were 2.7 (95% CI -13.4 to 18.9) kg, 3.9 (95% CI -15.1 to 22.9) kg, 3.2 (95% CI -16.7 to 23.1) kg; and the numbers of subjects who would have a clinically important error were 29 (55.7%), 29 (56.9%), and 30 (51.7%) for the McLaren-Read, Moore, and body mass index methods, respectively.ConclusionsThe majority of the subjects demonstrated a clinically important error between the actual body weight and the IBW. The percent error increased in subjects > 25 kg actual body weight. These data underline the importance of obtaining height measurements and calculated IBW in pediatric patients who are mechanically ventilated.Copyright © 2018 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.