• Anaesth Intensive Care · May 2018

    Review Meta Analysis

    Effect on neonatal outcome of pharmacological interventions for attenuation of the maternal haemodynamic response to tracheal intubation: a systematic review.

    Although slightly lowering 5 minute Apgar scores, opioids used to attenuate the maternal pressor response to intubation did not have clinically significant effects on neonates.

    pearl
    • A Aman, B Salim, K Munshi, S A Raza, and F A Khan.
    • Fellow, Obstetric Anesthesia, Department of Anaesthesiology, Aga Khan University, Pakistan.
    • Anaesth Intensive Care. 2018 May 1; 46 (3): 258271258-271.

    AbstractThe primary aim of this systematic review was to assess the effect on neonatal outcome of pharmacological interventions used for attenuation of the haemodynamic response to tracheal intubation in patients undergoing caesarean section under general anaesthesia. A systematic search of randomised controlled trials from 1990 to 2015 was conducted. The primary outcome measure was the Apgar score at five minutes and secondary outcomes were umbilical arterial blood gas parameters and neurological adaptive capacity scores. Twenty-seven randomised controlled trials (1,689 patients) were included in the qualitative synthesis. Only five studies using opioids (383 patients) and five studies using non-opioid analgesics (358 patients) were subjected to meta-analysis. The Apgar score at five minutes was significantly lower in neonates of opioid-treated mothers (mean difference: -0.29, 95% confidence interval -0.56 to -0.02, P-value=0.03) compared to mothers in the control group; the umbilical arterial pH was lower and there was a higher requirement for tactile stimulation in neonates. No difference was seen in Apgar scores of neonates of mothers administered non-opioid analgesics compared to placebo. No difference was observed in other parameters between opioid- or non-opioid-treated mothers. This review suggests that opioid interventions for attenuation of the haemodynamic response to tracheal intubation in pregnant patients under general anaesthesia affect neonatal Apgar scores at five minutes in neonates but the difference did not appear to be clinically meaningful. We were unable to demonstrate any difference in safety.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

    pearl
    1

    Although slightly lowering 5 minute Apgar scores, opioids used to attenuate the maternal pressor response to intubation did not have clinically significant effects on neonates.

    Daniel Jolley  Daniel Jolley
     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..