-
- Dayane de Melo Costa, Lillian Kelly de Oliveira Lopes, Karen Vickery, Evandro Watanabe, Lara Stefania Netto de Oliveira Leão Vasconcelos, Milena Cristina de Paula, Dulcelene Sousa Melo, Honghua Hu, Anand Kumar Deva, and Anaclara Ferreira Veiga Tipple.
- Faculty of Nursing, Federal University of Goias, Goiânia, Goiás, Brazil; Surgical Infection Research Group, Faculty of Medicine and Health Sciences, Sydney, New South Wales, Australia.
- Injury. 2018 Nov 1; 49 (11): 2005-2012.
BackgroundThe acquisition of reusable surgical instruments (RSIs) through loaner system is a worldwide phenomenon, particularly in orthopaedic surgeries. Loaner sets contain high-complex design RSIs, which are very difficult to clean, and also include single use implants, such as screws, that remain in the surgical tray and are subjected to multiple reprocessing until they are implanted. Inadequate cleaning of SI and various exposures of single-use implants to physical, chemical and biological agents can compromise their quality/safety and promote biofilm formation. The difficulty in cleaning is compounded in middle and low-income countries where automated cleaning infrastructure at sterilizing service units is often unavailable, and thus manual cleaning only is performed. Thus, we aimed to determine the condition of orthopaedic loaned sets when delivered to the hospital, assess the quality of complex-design RSIs reprocessed by manual cleaning, and evaluate the effect of multiple reprocessing on single-use implant (screw).MethodsFlexible medullary reamers (FMRs), depth gauges and screws used for femur intramedullary nailing, in clinical use for >1 year, were obtained from three Brazilian loaner companies and assessed for residual ATP, protein, bacterial contamination, endotoxin and/or biofilm at delivery at the hospital, following cleaning and steam sterilisation.ResultsBefore cleaning, blood was visible on a RSIs tray, and RSIs/screws were contaminated with high amounts of ATP, protein and bacteria. Visible soil was released during brushing of a FMR lumen and, following cleaning, the inner layer of 34/40 were visible soiled, and over 5/8 were protein test positive. Following sterilisation, biofilm and soil, including fragments appearing to be bone, were detected by scanning electron microscopy on RSIs/screws. A sterilised FMR revealed visible soil on the inner layer. Endotoxin tests were negative.ConclusionThe contaminated condition of loaned-complex-designed RSIs/screws upon arrival at the hospital and after reprocessing points to the insufficiency of manual reprocessing and management practices related to this instruments/implants. A multidisciplinary approach involving expert in design/manufacture, regulating, managing, reprocessing and surgeons is suggested to improve RSIs manufacture that enables complete decontamination and maintain the surgical patient safety.Copyright © 2018 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.