• Heart Lung · Nov 2017

    Review Meta Analysis

    Apnoeic oxygenation during intubation in the intensive care unit: A systematic review and meta-analysis.

    • Matthew J Binks, Rhys S Holyoak, Thomas M Melhuish, Ruan Vlok, Anthony Hodge, Thomas Ryan, and Leigh D White.
    • Wagga Wagga Rural Referral Hospital, NSW, Australia; Faculty of Medicine, University of New South Wales, NSW, Australia. Electronic address: m.binks@unsw.edu.au.
    • Heart Lung. 2017 Nov 1; 46 (6): 452-457.

    AbstractHypoxaemia increases the risk of cardiac arrest and mortality during intubation. The reduced physiological reserve and reduced efficacy of pre-oxygenation in intensive care patients makes their intubation particularly dangerous. Apnoeic oxygenation is a promising means of preventing hypoxaemia in this setting. We sought to ascertain whether apnoeic oxygenation reduces the incidence of hypoxaemia when used during endotracheal intubation in the intensive care unit (ICU). A systematic review of five databases for all relevant studies published up to November 2016 was performed. Eligible studies investigated apnoeic oxygenation during intubation in the ICU, irrespective of design. All studies were assessed for risk of bias and level of evidence. A meta-analysis was performed on all data using Revman 5.3. Six studies including 518 patients were retrieved. The study found level 1 evidence of a significant reduction in the incidence of critical desaturation (RR = 0.69, CI = 0.48-1.00, p = 0.05) and a significant increase in the lowest SpO2 value by 2.83% (CI = 2.28-3.38, p < 0.00001). There was a significant reduction in ICU stay (WMD = -2.89, 95%CI = -3.25 to -2.51, p < 0.00001). There was no significant difference between groups regarding mortality (RR = 0.77, 95%CI = 0.59-1.03, p = 0.08), first pass intubation success (RR = 1.17, 95%CI = 0.67 to 2.03, p = 0.58), arrhythmia during intubation (RR = 0.58, 95%CI = 0.08 to 4.29, p = 0.60), cardiac arrest during intubation (RR = 0.33, 95%CI = 0.01 to 7.84, p = 0.49) and duration of ventilation (WMD = -1.97, 95%CI = -5.89 to 1.95, p = 0.32). Apnoeic oxygenation reduces patient hypoxaemia during intubation performed in the ICU. This meta-analysis found evidence that apnoeic oxygenation may significantly reduce the incidence of critical desaturation and significantly raises the minimum recorded SpO2 in this setting. We recommend apnoeic oxygenation be incorporated into ICU intubation protocol.Copyright © 2017 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…