    An evaluation of a new combined Spo2/PtcCO2 sensor in very low birth weight infants.

    • Serafina Lacerenza, Maria Pia De Carolis, Francesca Paola Fusco, Giuseppe La Torre, Giacomina Chiaradia, and Costantino Romagnoli.
    • Division of Neonatology, Department of Pediatrics, Institute of Hygiene, Catholic University of Sacred Heart, Rome, Italy.

    BackgroundRecently, a new sensor for combined assessment of pulse oximetry oxygen saturation (Spo(2)) and transcutaneous monitoring of carbon dioxide partial pressure (PtcCO(2)) has been introduced (TOSCA 500, Radiometer basel AG, Switzerland) [corrected] We designed this study to evaluate the usability and reliability of TOSCA in neonates with birth weight MethodsIn a prospective study of 22 newborns, TOSCA was tested, positioning the sensor on the ear pinna with an adhesive attachment clip. Simultaneous monitoring with TOSCA, conventional pulse oximeter (HP; Datex Ohmeda 3740), and a transcutaneous device (TINA TCM3, Radiometer, Copenhagen) was performed for 60 min. PtcCO(2) measurement from TOSCA (PtcCO(2TOSCA)) and TINA (PtcCO(2)) were compared with Pco(2) from blood samples (PCO(2EAB)) at 1 and 60 min. During the monitoring period, values of PtcCO(2TOSCA) were compared with PtcCO(2), and SatO(2) values from TOSCA with those from a pulse oximeter. Corresponding data were compared using Bland-Altman analysis.ResultsBias (precision) at 1 min and at 60 min between PCO(2EAB) and PtcCO(2) values were 3.5 (12.4) mm Hg and 2.8 (10.2), respectively, whereas between PCO(2EAB) and PtcCO(2TOSCA) values were 18.3 (30.4) mm Hg and 1.8 (25) mm Hg. Bland-Altman analysis shows a better correspondence PtcCO(2)/PtcCO(2TOSCA) between 7 and 15 min. No significant differences were found between Spo(2) and SpO(2TOSCA).ConclusionsThe TOSCA monitor is safe and easy to apply in very low birth weight newborns. The pulse oximeter measurements may be useful for titrating oxygen therapy. Pco(2) measurement with TOSCA is most useful as a trend and independent confirmation of arterial Pco(2) is required if an accurate value is needed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…