J. Thorac. Cardiovasc. Surg. · Jan 2019
Thirty-year experience with a bileaflet mechanical valve prosthesis.
- Scott Johnson, Martha R Stroud, John M Kratz, Scott M Bradley, Fred A Crawford, and John S Ikonomidis.
- Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, SC.
- J. Thorac. Cardiovasc. Surg. 2019 Jan 1; 157 (1): 213-222.
BackgroundThe objective was to evaluate the long-term outcomes of the St Jude Medical (Saint Paul, Minn) mechanical valve prosthesis implantation.MethodsSince 1979, every patient receiving this prosthesis has been followed annually.ResultsFrom January 1979 to December 2014, 1023 patients were accrued. Patients' ages ranged from 18 to 85 years. Aortic valve replacement was performed in 584 patients, and mitral valve replacement was performed in 439 patients. Follow-up was 95% complete. Operative mortality was 3% (17/584, aortic valve replacement) and 4% (18/439, mitral valve replacement). In patients undergoing aortic valve replacement, late actuarial survival was 62% ± 2%, 32% ± 2%, and 14% ± 3% at 10, 20, and 30 years, respectively. Thirty-year freedom from reoperation, thromboembolism, valve thrombosis, bleeding, and endocarditis was 92% ± 2%, 79% ± 3%, 96% ± 1%, 56% ± 5%, and 92% ± 2%, respectively. In patients undergoing mitral valve replacement, late actuarial survival was 64% ± 3%, 28% ± 3%, and 14% ± 3% at 10, 20, and 30 years, respectively. Thirty-year freedom from reoperation, thromboembolism, valve thrombosis, bleeding, and endocarditis was 85% ± 5%, 55% ± 6%, 99% ± 1%, 57% ± 6%, and 95% ± 2%, respectively. The incidence of bleeding was 2.5% and 2.0% per patient-year for aortic valve replacement and mitral valve replacement, respectively. The incidence of thromboembolism was 1.6% and 2.9% per patient-year for aortic valve replacement and mitral valve replacement, respectively.ConclusionsAnnual follow-up of all of our patients receiving a St Jude Medical mechanical valves prosthesis has allowed better identification valve-related issues and events. After 3 decades of observation with close follow-up, the St Jude Medical mechanical valve continues to be a reliable prosthesis.Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.