Critical care medicine · Feb 2019
Esophageal Doppler Can Predict Fluid Responsiveness Through End-Expiratory and End-Inspiratory Occlusion Tests.
- François Dépret, Mathieu Jozwiak, Jean-Louis Teboul, Jean-Emmanuel Alphonsine, Christian Richard, and Xavier Monnet.
- Hôpitaux universitaires Paris-Sud, Hôpital de Bicêtre, service de réanimation médicale, 78, rue du Général Leclerc, Le Kremlin-Bicêtre, F-94270, France.
- Crit. Care Med. 2019 Feb 1; 47 (2): e96-e102.
ObjectivesTo assess whether, in patients under mechanical ventilation, fluid responsiveness is predicted by the effects of short respiratory holds on cardiac index estimated by esophageal Doppler.DesignProspective, monocentric study.SettingMedical ICU.PatientsTwenty-eight adult patients with acute circulatory failure and a decision of the clinicians in charge to administer fluids.InterventionsBefore and after infusing 500 mL of saline, we measured cardiac index estimated by esophageal Doppler before and during the last 5 seconds of successive 15-second end-inspiratory occlusion and end-expiratory occlusion, separated by 1 minute. Patients in whom volume expansion increased cardiac index measured by transpulmonary thermodilution greater than or equal to 15% were defined as "fluid responders." Cardiac index measured by the Pulse Contour Cardiac Output device (from pulse contour analysis or transpulmonary thermodilution) was used as the reference.Measurements And Main ResultsEnd-expiratory occlusion increased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (8% ± 2% vs 3% ± 1%, respectively; p < 0.0001) and end-inspiratory occlusion decreased cardiac index estimated by esophageal Doppler more in responders than in nonresponders (-8% ± 5% vs -4% ± 2%, respectively; p = 0.0002). Fluid responsiveness was predicted by the end-expiratory occlusion induced percent change in cardiac index estimated by esophageal Doppler with an area under the receiver operating characteristic curve of 1.00 (95% CI, 0.88-1.00) and a threshold value of 4% increase in cardiac index estimated by esophageal Doppler. It was predicted by the sum of absolute values of percent changes in cardiac index estimated by esophageal Doppler during both occlusions with a similar area under the receiver operating characteristic curve (0.99 [0.86-1.00]) and with a threshold of 9% change in cardiac index estimated by esophageal Doppler, which is compatible with the esophageal Doppler precision.ConclusionsIf the absolute sum of the percent change in cardiac index estimated by esophageal Doppler induced by two successive end-inspiratory occlusion and end-expiratory occlusion maneuvers is greater than 9%, it is likely that a 500 mL fluid infusion will increase cardiac output. This diagnostic threshold is higher than if only end-expiratory occlusion induced percent changes in cardiac index estimated by esophageal Doppler are taken into account.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.