• Shock · Dec 2018

    Noninvasive Assessment of Intra-Abdominal Pressure Using Ultrasound-Guided Tonometry: A Proof-of-Concept Study.

    • Andreas Bloch, Michael Glas, Andreas Kohler, Ulrich Baumann, and Stephan M Jakob.
    • Department of Intensive Care Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
    • Shock. 2018 Dec 1; 50 (6): 684-688.

    BackgroundIntra-abdominal hypertension jeopardizes abdominal organ perfusion and venous return. Contemporary recognition of elevated intra-abdominal pressure (IAP) plays a crucial role in reducing mortality and morbidity. We evaluated ultrasound-guided tonometry in this context hypothesizing that the vertical chamber diameter of this device inversely correlates with IAP.MethodsIAP was increased in six 5 mmHg steps to 40 mmHg by instillation of normal saline into the peritoneal cavity of eight anesthetized pigs. Liver and renal blood flows (ultrasound transit time), intravesical, intraperitoneal, and end-inspiratory plateau pressures were recorded. For ultrasound-based assessment of IAP (ultrasound-guided tonometry), a pressure-transducing, compressible chamber was fixed at the tip of a linear ultrasound probe, and the system was applied on the abdominal wall using different predetermined levels of external pressure. At each IAP level (reference: intravesical pressure), two investigators measured the vertical diameter of this chamber.ResultsAll abdominal flows decreased (by 39%-58%), and end-inspiratory plateau pressure increased from 15 mbar (14-17 mbar) to 38 mbar (33-42 mbar) (median, range) with increasing IAP (all P < 0.01). Vertical chamber diameter decreased from 14.9 (14.6-15.2) mm to12.8 (12.4-13.4) mm with increasing IAP. Coefficients of variations between and within observers regarding change of the vertical tonometry chamber diameter were small (all <4%), and the results were independent of the externally applied pressure level on the ultrasound probe. Correlation of IAP and vertical pressure chamber distance was highly significant (r = -1, P = 0.0004). Ultrasound-guided tonometry could discriminate between normal (baseline) pressure and 15 mmHg, between 15 and 25 mmHg) and between 25 and 40 mmHg IAP (all P ≤ 0.18). Similar results were obtained for end-inspiratory plateau pressures.ConclusionsIn our model, values obtained by ultrasound-guided tonometry correlated significantly with IAPs. The method was able to discriminate between normal, moderately, and markedly increased IAP values.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.