• Paediatric anaesthesia · Apr 2012

    Randomized Controlled Trial Comparative Study

    The Size 1 ProSeal™ laryngeal mask airway in infants: a randomized, noncrossover study with the Classic™ laryngeal mask airway.

    • Maite López-Gil, Ignacio Mantilla, Teresa Blanco, Enrique Teigell, Mónica Hervias, and Rosa Fernández-López.
    • Department of Anaesthesia and Reanimation, Gregorio Marañón University Hospital, Madrid, Spain. mlopezgi@yahoo.es
    • Paediatr Anaesth. 2012 Apr 1;22(4):365-70.

    BackgroundIn recent years, numerous scientific publications have endorsed the superiority of the ProSeal™ laryngeal mask airway (PLMA) over the Classic™ laryngeal mask airway (cLMA) in adults, children, and infants. The PLMA forms a better seal for both the respiratory and gastrointestinal tracts, provides easier access to the gastrointestinal tract, and exerts lower mucosal pressures for a given seal pressure. This study aims to determine whether this superiority can also be observed for the size 1 PLMA used in anesthetized neonates and infants with positive pressure ventilation.MethodsSixty consecutive neonates and infants undergoing elective surgical procedures were randomized to airway management with the size 1 PLMA or cLMA. For all patients, we recorded ease of insertion, effective airway time, number of placement attempts, oropharyngeal leak pressure, fiberoptic position, audible leaks, mask displacement, number of reinsertions during maintenance, gastric insufflation, and frequency of blood stain.ResultsEase of insertion, successful insertion in <3 attempts, fiberoptic position of the airway tube, and frequency of blood stain were similar in both groups. Effective airway time was lower for the PLMA group (30.5 vs 35.6 s). Oropharyngeal leak pressure was higher with the PLMA (32.9 vs 22.2 cm H(2)O, P < 0.001) and gastric insufflation less common (0% vs 6%, P = 0.492). There were fewer mask displacements during maintenance of anesthesia with the PLMA (0% vs 26.7%, P < 0.001). Mask reinsertion was not necessary during maintenance of anesthesia with the PLMA, although it was necessary in 14 cases in the cLMA group (0% vs 46%, P < 0.001). Audible leaks were less common with the PLMA (0% vs 46%, P < 0.001).ConclusionsWe conclude that the size 1 PLMA is a stable, safe, and efficacious airway control device during neonatal and infant anesthesia, allowing higher peak airway pressure during positive pressure ventilation, with fewer mask displacements and gastric insufflations than the cLMA.© 2012 Blackwell Publishing Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…