J. Cardiothorac. Vasc. Anesth. · Jun 2019
Comparative StudyA Comparative Study of SEER Sonorheometry Versus Standard Coagulation Tests, Rotational Thromboelastometry, and Multiple Electrode Aggregometry in Cardiac Surgery.
- Ekaterina Baryshnikova, Umberto Di Dedda, and Marco Ranucci.
- Department of Cardiovascular Anaesthesia and Intensive Care Unit, IRCCS Policlinico San Donato, San Donato Milanese (Milan), Milan, Italy.
- J. Cardiothorac. Vasc. Anesth. 2019 Jun 1; 33 (6): 1590-1598.
ObjectivesCoagulation point-of-care tests for the diagnosis and management of bleeding commonly are used in cardiac surgery. Recently, a new viscoelastic point-of-care device, Quantra (HemoSonics, Charlottesville, VA), which is based on sonic estimation of elasticity via resonance sonorheometry, entered the market. Prior studies have compared the Quantra parameters with conventional coagulation tests and thromboelastography or rotational thromboelastography, but no study has assessed the correlation of the platelet-derived Quantra parameter platelet contribution to stiffness (PCS) with platelet function assays. The present study compared the Quantra-derived coagulation parameters with conventional coagulation tests, rotational thromboelastography-derived parameters, and platelet function measured using multiplate aggregometry.DesignProspective cohort study.SettingUniversity research hospital.ParticipantsThe study comprised 30 cardiac surgery patients before and after cardiopulmonary bypass.InterventionsNone.Measurements And Main ResultsQuantra clot stiffness showed a very strong correlation with the EXTEM maximum clot firmness before and after cardiopulmonary bypass and in the overall samples (r values 0.94-0.96). Quantra fibrinogen contribution to stiffness was compared with the corresponding FIBTEM and Clauss fibrinogen levels, which also showed a strong level of correlation (r values between 0.74 and 0.87). Quantra PCS strongly correlated with platelet count (r = 0.71) in the overall samples and moderately with adenosine diphosphate-dependent platelet function (r = 0.67). In a multivariable model, both the adenosine diphosphate test value and the platelet count remained independently associated with Quantra PCS.ConclusionsFibrinogen-dependent clot stiffness properties are well-reflected by the Quantra fibrinogen contribution to stiffness parameter, and PCS incorporates platelet count and function.Copyright © 2019. Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.