• Ann. Thorac. Surg. · Mar 1985

    Comparative Study

    A comparison of flow gradients across disposable arterial perfusion cannulas.

    • R Brodman, H Siegel, M Lesser, and R Frater.
    • Ann. Thorac. Surg. 1985 Mar 1; 39 (3): 225-33.

    AbstractFive-hundred members of The Society of Thoracic Surgeons were canvassed to discover which cannulas are currently used for open-heart surgical procedures in adults; 120 surgeons responded. The mean arterial line pressure produced by 29 disposable arterial perfusion cannulas (size range, 16F to 30F) at flow rates of 1 to 5 liters per minute was compared. A roller pump with perfusion tubing 95 mm (0.75 inch) in diameter was used with water as the test solution. Line pressures in these cannulas ranged from 22.4 +/- 2.30 (standard deviation) to 271.0 +/- 6.60 mm Hg at 5 L/min. Four 24F cannulas had gradients of less than 55 mm Hg at a flow rate of 5 L/min, and 6 cannulas--4 of which were 22F and 2, 24F--had gradients higher than 150 mm Hg at 5 L/min. A number of cannulas kinked easily, and these showed marked increases in line pressure. The following results were obtained from this study: (1) a wide range of line pressures was observed in disposable arterial perfusion cannulas currently in clinical use; (2) some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; and (3) both material and design affect function, with some designs being safer than others. Cardiac surgeons should base the choice of an arterial perfusion cannula on the best performance and safest design available to avoid cannula-related problems at operation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.