-
Meta Analysis Comparative Study
Drug-eluting or bare-metal stents for percutaneous coronary intervention: a systematic review and individual patient data meta-analysis of randomised clinical trials.
- Raffaele Piccolo, Kaare H Bonaa, Orestis Efthimiou, Olivier Varenne, Andrea Baldo, Philip Urban, Christoph Kaiser, Wouter Remkes, Lorenz Räber, Adam de Belder, van 't Hof Arnoud W J AWJ Department of Cardiology, Isala Heart Centre, Zwolle, Netherlands; Department of Cardiology, Maastricht University Medical Center, Netherlands; , Goran Stankovic, Pedro A Lemos, Tom Wilsgaard, Jörg Reifart, Alfredo E Rodriguez, Expedito E Ribeiro, Serruys Patrick W J C PWJC International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College, London, London, UK., Alex Abizaid, Manel Sabaté, Robert A Byrne, Jose M de la Torre Hernandez, William Wijns, Peter Jüni, Stephan Windecker, Marco Valgimigli, and Coronary Stent Trialists' Collaboration.
- Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy.
- Lancet. 2019 Jun 22; 393 (10190): 2503-2510.
BackgroundNew-generation drug-eluting stents (DES) have mostly been investigated in head-to-head non-inferiority trials against early-generation DES and have typically shown similar efficacy and superior safety. How the safety profile of new-generation DES compares with that of bare-metal stents (BMS) is less clear.MethodsWe did an individual patient data meta-analysis of randomised clinical trials to compare outcomes after implantation of new-generation DES or BMS among patients undergoing percutaneous coronary intervention. The primary outcome was the composite of cardiac death or myocardial infarction. Data were pooled in a one-stage random-effects meta-analysis and examined at maximum follow-up and a 1-year landmark. Risk estimates are reported as hazard ratios (HRs) with 95% CIs. This study is registered in PROSPERO, number CRD42017060520.FindingsWe obtained individual data for 26 616 patients in 20 randomised trials. Mean follow-up was 3·2 (SD 1·8) years. The risk of the primary outcome was reduced in DES recipients compared with BMS recipients (HR 0·84, 95% CI 0·78-0·90, p<0·001) owing to a reduced risk of myocardial infarction (0·79, 0·71-0·88, p<0·001) and a possible slight but non-significant cardiac mortality benefit (0·89, 0·78-1·01, p=0·075). All-cause death was unaffected (HR with DES 0·96, 95% CI 0·88-1·05, p=0·358), but risk was lowered for definite stent thrombosis (0·63, 0·50-0·80, p<0·001) and target-vessel revascularisation (0·55, 0·50-0·60, p<0·001). We saw a time-dependent treatment effect, with DES being associated with lower risk of the primary outcome than BMS up to 1 year after placement. While the effect was maintained in the longer term, there was no further divergence from BMS after 1 year.InterpretationThe performance of new-generation DES in the first year after implantation means that BMS should no longer be considered the gold standard for safety. Further development of DES technology should target improvements in clinical outcomes beyond 1 year.FundingBern University Hospital.Copyright © 2019 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.