• JAMA surgery · Apr 2017

    Fixed-Distance Model for Balloon Placement During Fluoroscopy-Free Resuscitative Endovascular Balloon Occlusion of the Aorta in a Civilian Population.

    • Pierre Pezy, Alexandros N Flaris, Nicolas J Prat, François Cotton, Peter W Lundberg, Jean-Louis Caillot, Jean-Stéphane David, and Eric J Voiglio.
    • Ministère de la Défense, Service de Santé des Armées, Ecole de Santé des Armées, Lyon-Bron, France2Unité Mixte de Recherche T9405, Laboratoire d'Anatomie, Faculté de Médecine Lyon Est, Université Lyon 1, Lyon, France.
    • JAMA Surg. 2017 Apr 1; 152 (4): 351-358.

    ImportanceResuscitative endovascular balloon occlusion of the aorta (REBOA) is an innovative procedure in the treatment of noncompressible truncal hemorrhage. However, readily available fluoroscopy remains a limiting factor in its widespread implementation. Several methods have been proposed to perform REBOA without fluoroscopic guidance, and these methods were adapted predominantly from the military theater.ObjectiveTo develop a method for performing REBOA in a civilian population using a standardized distance from a set point of entry.Design, Setting, And ParticipantsA retrospective study of whole-body computed tomographic (CT) scans from a cohort of 280 consecutive civilian trauma patients from University Hospitals of Lyon, France, was used to calculate the endovascular distances from both femoral arteries at the level of the upper border of the symphysis pubis to aortic zone I (descending thoracic aorta) and zone III (infrarenal aorta). These whole-body CT scans were performed between 2013 and 2015. Data were analyzed from July 16 to December 7, 2015.Main Outcomes And MeasuresTwo segments (1 per zone) common to all CT scans were isolated, and their location, length, prevalence in the cohort, and predicted prevalence in the general population were calculated by inverting 99% certainty tolerance limits.ResultsAmong the 280 trauma patients (140 men and 140 women) in this study, the mean (SD) height was 170.7 (8.7) cm, and the mean (SD) age was 38.8 (16.5) years. The common segment in zone I (414-474 mm) existed in all CT scans. The common segment in zone III (236-256 mm) existed in 99.6% and 97.9% of CT scans from the right and left femoral arteries, respectively. These segments are expected to exist in 98.7% (zone I) and 94.9% (zone III) of the general population.Conclusions And RelevanceTarget distances for blind placement of REBOA exist with more than 94% prevalence in a civilian population. These findings support the expanded use of REBOA in emergency department and prehospital settings. Validation for safety and efficacy on cadaveric and clinical models is necessary.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.