-
- Jennifer H Kang, G Clay Sherill, Saurabh R Sinha, and Christa B Swisher.
- Department of Neurology, Duke University Medical Center, DUMC 2905, Durham, NC, 27710, USA. Jennifer.kang@duke.edu.
- Neurocrit Care. 2019 Oct 1; 31 (2): 312-320.
BackgroundNon-convulsive seizures (NCS) are a common occurrence in the neurologic intensive care unit (Neuro-ICU) and are associated with worse outcomes. Continuous electroencephalogram (cEEG) monitoring is necessary for the detection of NCS; however, delays in interpretation are a barrier to early treatment. Quantitative EEG (qEEG) calculates a time-compressed simplified visual display from raw EEG data. This study aims to evaluate the performance of Neuro-ICU nurses utilizing bedside, real-time qEEG interpretation for detecting recurrent NCS.MethodsThis is a prospective, single-institution study of patients admitted to the Duke Neuro-ICU between 2016 and 2018 who had NCS identified on traditional cEEG review. The accuracy of recurrent seizure detection on hourly qEEG review by bedside Neuro-ICU nurses was compared to the gold standard of cEEG interpretation by two board-certified neurophysiologists. The nurses first received brief qEEG training, individualized for their specific patient. The bedside qEEG display consisted of rhythmicity spectrogram (left and right hemispheres) and amplitude-integrated EEG (left and right hemispheres) in 1-h epochs.ResultsTwenty patients were included and 174 1-h qEEG blocks were analyzed. Forty-seven blocks contained seizures (27%). The sensitivity was 85.1% (95% CI 71.1-93.1%), and the specificity was 89.8% (82.8-94.2%) for the detection of seizures for each 1-h block when compared to interpretation of conventional cEEG by two neurophysiologists. The false positive rate was 0.1/h. Hemispheric seizures (> 4 unilateral EEG electrodes) were more likely to be correctly identified by nurses on qEEG than focal seizures (≤ 4 unilateral electrodes) (p = 0.03).ConclusionsAfter tailored training sessions, Neuro-ICU nurses demonstrated a good sensitivity for the interpretation of bedside real-time qEEG for the detection of recurrent NCS with a low false positive rate. qEEG is a promising tool that may be used by non-neurophysiologists and may lead to earlier detection of NCS.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.