• Prehosp Emerg Care · Sep 2020

    Randomized Controlled Trial

    A Randomized Crossover Trial of Conventional versus Modified "Koch" Chest Compressions in a Height-Restricted Aeromedical Helicopter.

    • Nick Pompa, Matthew J Douma, Priya Jaggi, Shell Ryan, Mark MacKenzie, and Domhnall O'Dochartaigh.
    • Prehosp Emerg Care. 2020 Sep 1; 24 (5): 704-711.

    AbstractAim: Low overhead height can negatively affect chest compression performance. An adapted compression technique has been proposed by paramedic H. Koch (pron. "Cook"). This study compares conventional to Koch technique in a height-restricted aeromedical helicopter. Methods: Eighteen clinicians were randomized to 2 minutes of conventional or Koch compressions, then crossed-over. Koch technique uses a forearm/elbow instead of overlapping hands. Compression quality was assessed with a Skill Reporting Laerdal Resusci-Anne manikin. Quality variables were: the number and rate of compressions, compression depth, release, land marking, and overall aggregate quality score. Participant feedback was collected using the Borg Scale of Perceived Exertion, and compression difficulty using a zero-to-ten scale. Furthermore, we solicited open-ended descriptive responses. Results: The average overall quality score was 63% for conventional compressions versus 79% for Koch compressions (p = 0.04). On average, the Koch compression method increased compression depth by 5 mm (95% CI 4.3 to 5.7) and the proportion of compressions at the correct depth by 17% (95% CI 7.55 to 26.45), although these were not statistically significant. Correct release and land marking showed no statistically significant difference between techniques. Koch compressions resulted in statistically significant reductions in physical exertion and difficulty (p < 0.001). Qualitative feedback described modified compressions as easier and more sustainable. Conclusions: In a height-restricted aeromedical helicopter, the average overall quality score improved using Koch compressions, although the mean rate, mean depth, correct release and land marking were found to be similar between techniques. Qualitative feedback described Koch compressions as easier and more sustainable. In settings where the compressor is affected by reduced overhead working height, Koch compressions may be an advisable alternative.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…