• Eur Spine J · Mar 2020

    A novel tool to provide predictable alignment data irrespective of source and image quality acquired on mobile phones: what engineers can offer clinicians.

    • Teng Zhang, Chuang Zhu, Qiaoyun Lu, Jun Liu, Ashish Diwan, and Cheung Jason Pui Yin JPY 0000-0002-7052-0875 Division of Spine Surgery, Department of Orthopaedics and Traumatology, Queen Mary Hospital, The Universi.
    • Division of Spine Surgery, Department of Orthopaedics and Traumatology, Queen Mary Hospital, The University of Hong Kong, 5/F Professorial Block, Pokfulam, Hong Kong. tgzhang@hku.hk.
    • Eur Spine J. 2020 Mar 1; 29 (3): 387-395.

    PurposeExisting automated spine alignment is based on original X-rays that are not applicable for teleradiology for spinal deformities patients. We aim to provide a novel automated vertebral segmentation method enabling accurate sagittal alignment detection, with no restrictions imposed by image quality or pathology type.MethodsA total of 428 optical images of original sagittal X-rays taken by smartphones or screenshots for consecutive patients attending our spine clinic were prospectively collected. Of these, 300 were randomly selected and their vertebrae were labelled with Labelme. The ground truth was specialists measured sagittal alignment parameters. Pre-trained Mask R-CNN was fine-tuned and trained to predict the vertebra level(s) on the remaining 128 testing cases. The sagittal alignment parameters including the thoracic kyphosis (TK), lumbar lordosis (LL) and sacral slope (SS) were auto-detected, based on the segmented vertebra. Dice similarity coefficient (DSC) and mean intersection over union (mIoU) were calculated to evaluate the accuracy of the predicted vertebra. The detected sagittal alignments were then quantitatively compared with the ground truth.ResultsThe DSC was 84.6 ± 3.8% and mIoU was 72.1 ± 4.8% indicating accurate vertebra prediction. The sagittal alignments detected were all strongly correlated with the ground truth (p < 0.001). Standard errors of the estimated parameters had a small difference from the specialists' results (3.5° for TK and SS; 3.4° for LL).ConclusionThis is the first study using fine-tuned Mask R-CNN to predict vertebral locations on optical images of X-rays accurately and automatically. We provide a novel alignment detection method that has a significant application on teleradiology aiding out-of-hospital consultations. These slides can be retrieved under Electronic Supplementary Material.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…