• J Obstet Gynaecol · Aug 2020

    Observational Study

    The influence of Body Roundness Index on sensorial block level of spinal anaesthesia for elective caesarean section: an observational study.

    • Betul Kozanhan, Omer Bardak, Sami Tutar Mahmut M http://orcid.org/0000-0002-5709-6504 Department of Anesthesiology and Reanimation, Konya Research and Education Hospital, Konya, T, Sibel Ozler, Munise Yildiz, and Ibrahim Solak.
    • Department of Anesthesiology and Reanimation, Konya Research and Education Hospital, Konya, Turkey.
    • J Obstet Gynaecol. 2020 Aug 1; 40 (6): 772-778.

    AbstractIn this prospective trial, we investigate the effectiveness of maternal Body Roundness Index in predicting the spread of spinal anaesthesia and vasopressor requirement in parturients receiving spinal anaesthesia during the elective caesarean section. We prospectively enrolled 175 parturients. Spinal anaesthesia performed with 10 mg 0.5% hyperbaric bupivacaine at the L3-L4 intervertebral space and the optimal cut-off points of the BRI evaluated as 6.59 by receiver operating characteristic analysis calculating area under the curve. Parturients were divided into two groups with BRI <6.59 and BRI ≥6.59 for analyses. Multivariate logistic regression analysis was used to test for a relationship between variables and maximum sensory block level and vasopressor requirement. BRI was found as an independent risk factor associated with maximum sensory block level (OR = 1.378, 95% CI: 1.125-1.687, p = 0.002). Hypotension and bradycardia events after spinal anaesthesia was not associated with BRI and other variables. The present study indicates that BRI was a practical tool to predict spinal drug distribution in term parturients undergoing caesarean delivery.Impact statementWhat is already known on this subject? Spinal anaesthesia is a commonly used anaesthetic technique for the caesarean section. However, the spinal drug distribution is highly unpredictable. Anthropometric variables may predict the intrathecal drug distribution in parturients. Body Roundness Index (BRI) captures body circumference regarding height to predict body fat percentage, consider the shape of the human body as an ellipse. An ellipsoid body shape might affect the spread of spinal anaesthesia.What do the results of this study add? Our results show that the BRI was as an independent risk factor associated with maximum sensory block level in term parturients undergoing caesarean delivery.What are the implications of these findings for future clinical practice and/or further research? A future study would present the possibility to design a formula for the exact amount of local anaesthetic to be used in spinal anaesthesia with the aid of maternal BRI.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…