• Anesthesia and analgesia · Dec 2002

    Initial experience with a novel heat-exchanging catheter in neurosurgical patients.

    • Anthony G Doufas, Ozan Akça, Atul Barry, David A Petrusca, Mohammad-Irfan Suleman, Nobutada Morioka, John J Guarnaschelli, and Daniel I Sessler.
    • Outcomes Research Institute and Department of Anesthesiology, University of Louisville, KY 40202, USA. agdoufas@Louisville.edu
    • Anesth. Analg. 2002 Dec 1; 95 (6): 1752-6, table of contents.

    UnlabelledEven mild hypothermia provides marked protection against cerebral ischemia in animal models. Hypothermia may be of therapeutic value during neurosurgical procedures. However, current cooling systems often fail to induce sufficient hypothermia before the dura is opened. Furthermore, they usually fail to restore normothermia by the end of surgery, thus delaying extubation. We evaluated a new internal heat-exchanging catheter. Eight ASA physical status II-IV patients (29-72 yr) undergoing craniotomy were enrolled. After the induction of general anesthesia, we introduced the SetPoint catheter into the inferior vena cava via a femoral vein. The target core body temperature was 34 degrees C-34.5 degrees C. After reaching the target, core temperature was maintained until the dura was closed. Target core temperature was then set to 37.0 degrees C, and the patient was rewarmed as quickly as possible. Seven patients had a tumor resection, and one had an aneurysm clipped. The core-cooling rate was 3.9 degrees C +/- 1.6 degrees C/h, and the rewarming rate was 2.0 degrees C +/- 0.5 degrees C/h; core temperature was 35.9 degrees C +/- 0.2 degrees C by the end of surgery. Patients were subsequently kept normothermic for 3 h before the catheter was removed. No thrombus or other particulate material was identified on the extracted catheters. None of the patients suffered any complications that could be attributed to the SetPoint system or thermal management.ImplicationsBecause current systems for inducing therapeutic hypothermia are too slow, we tested an internal counter-current thermal management system during hypothermic neurosurgery. The SetPoint catheter cooled at 3.9 degrees C +/- 1.6 degrees C/h and rewarmed at 2.0 degrees C +/- 0.5 degrees C/h. Catheter-based internal thermal management thus seems to be rapid and effective.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.