• Eur Spine J · Apr 2020

    Does the external remote controller's reading correspond to the actual lengthening in magnetic-controlled growing rods?

    • Kar Hao Teoh, Abdul Nazeer Moideen, Kausik Mukherjee, Sridhar Kamath, Stuart H James, Alwyn Jones, John Howes, Paul R Davies, and Sashin Ahuja.
    • School of Engineering, Cardiff University, Queen's Buildings, The Parade, Cardiff, CF24 3AA, UK. teohkh@cardiff.ac.uk.
    • Eur Spine J. 2020 Apr 1; 29 (4): 779-785.

    PurposeMagnetic-controlled growing rods (MCGRs) are now routinely used in many centres to treat early-onset scoliosis (EOS). MCGR lengthening is done non-invasively by the external remote controller (ERC). Our experience suggests that there may be a discrepancy between the reported rod lengthening on the ERC and the actual rod lengthening. The aim of this study was to investigate this discrepancy.MethodsThis was a prospective series. Eleven patients who were already undergoing treatment for EOS using MCGRs were included in this study.ResultsOne hundred and ninety-two sets of ultrasound readings were obtained (96 episodes of rod lengthening on dual-rod constructs) and compared to their ERC readings. Only 15/192 (7.8%) readings were accurate; 27 readings (14.9%) were false positive; and 8 readings (4.2%) were an underestimation while 142 readings (74.0%) were an overestimation by the ERC. Average over-reporting by the ERC was 5.31 times of the actual/ultrasound reading. When comparing interval radiographs with lengthening obtained on ultrasound, there was a discrepancy with an average overestimation of 1.35 times with ultrasound in our series. There was a significant difference between ERC and USS (p = 0.01) and ERC and XR (p = 0.001). However, there was no significant difference between USS and XR (p > 0.99).ConclusionThe reading on the ERC does not equate to the actual rod lengthening. The authors would recommend that clinicians using the MCGR for the treatment of early-onset scoliosis include pre- and post-extension imaging (radiographs or ultrasound) to confirm extension lengths at each outpatient extension. In centres with ultrasound facilities, we would suggest that patients should have ultrasound to monitor each lengthening after distraction but also 6-month radiographs. These slides can be retrieved under Electronic Supplementary Material.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…