Clinical Trial Controlled Clinical Trial
Reversal of heparin anticoagulation by recombinant platelet factor 4 in humans.
Protamine is used to reverse the anticoagulant effects of heparin, but it can have important side effects. Platelet factor 4 (PF4) is a protein found in platelet alpha granules that binds to and thereby neutralizes heparin. We evaluated the safety and effectiveness of intravenous recombinant PF4 to neutralize heparin anticoagulation after cardiac catheterization in a phase 1, open-label trial. ⋯ rPF4, in doses ranging from 0.5 to 5.0 mg/kg over 3 minutes, had no serious side effects. Given in sufficient amounts, rPF4 can completely and rapidly reverse the anticoagulant effects of heparin.
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
Randomized study of implantable defibrillator as first-choice therapy versus conventional strategy in postinfarct sudden death survivors.
In retrospective studies of sudden cardiac death survivors, the implantable cardioverter-defibrillator (ICD) compares favorably with medical and surgical therapy. Thus, use of the conventional strategy of starting treatment with antiarrhythmic drugs (AD), at least in certain patient categories, may be questionable. The goal of this study was to analyze the effectiveness of ICD implantation as first-choice therapy versus the conventional therapeutic strategy of starting with AD. ⋯ These data suggest that ICD implantation as first choice is preferable to the conventional approach in survivors of cardiac arrest caused by old myocardial infarction. Conventionally treated patients are likely to end up with an ICD, and those who remain on AD as sole therapy have a high risk of death regardless of efficacy assessment, including PES.
-
Editorial Comment Randomized Controlled Trial Clinical Trial
Are implantable cardioverter-defibrillators better than conventional antiarrhythmic drugs for survivors of cardiac arrest?
-
It is thought that only a thin layer of tissue adjacent to the electrode is heated directly by electrical current (resistive heating) during radiofrequency ablation. Most of the thermal injury is thought to result from conduction of heat from the surface layer. The purpose of this study was to determine whether lesion depth could be increased by producing direct resistive heating deeper in the tissue with higher radiofrequency power, allowed by cooling the ablation electrode with saline irrigation to prevent the rise in impedance that occurs when the electrode-tissue interface temperature reaches 100 degrees C. ⋯ Saline irrigation maintains a low electrode-tissue interface temperature during radiofrequency application at high power, which prevents an impedance rise and produces deeper and larger lesions. A higher temperature in the tissue (3.5 mm deep) than at the electrode-tissue interface indicates that direct resistive heating occurred deeper
-
Since the clinical introduction of dynamic cardiomyoplasty, a discrepancy has been observed between unchanged measurements of cardiac function and improved clinical outcome. ⋯ By the left ventricular conductance catheter and aortic Modelflow methods, improvement in cardiac function by dynamic cardiomyoplasty was demonstrated in this patient group. The synchronization interval, stimulus strength, and stimulus duration appeared to be critical for obtaining optimal improvement.