Heart rhythm : the official journal of the Heart Rhythm Society
-
There are no recommendations on the optimal dosing for cryoablation of atrial fibrillation (Cryo-AF). ⋯ A novel Cryo-AF dosing algorithm guided by TT-PVI can help individualize the ablation strategy and yield improved procedural endpoints and efficiency as compared to a conventional, nonstandardized approach.