Acta orthopaedica
-
Background and purpose - COVID-19 lockdowns have resulted in noteworthy changes in trauma admissions. We report and compare the incidence and characteristics of severe injuries (New Injury Severity Score [NISS] > 15) during the COVID-19 lockdown in Finland with earlier years. Methods - We retrospectively analyzed incidence rate, injury severity scores, injury patterns, and mechanisms of injury of all severely injured patients (NISS >15) in 4 Finnish hospitals (Tampere University Hospital, Kuopio University Hospital, Central Finland Hospital, Mikkeli Central Hospital) during the 11-week lockdown period (March 16-May 31, 2020) with comparison with a matching time period in earlier years (2016-2018). ⋯ Interpretation - Despite heavy social restrictions, the incidence of severe injuries during the lockdown period was similar to previous years. Notably, a decline in road use and traffic volumes did not reduce the number of severe traffic accidents. Although our data is compatible with a decrease of 2.0 to an increase of 1.7 severely injured patients per 105 inhabitants, we conclude that severely injured patients do not disappear even during pandemic and stabile hospital resources are needed to treat these patients.
-
Randomized Controlled Trial Comparative Study
Reduced wear in vitamin E-infused highly cross-linked polyethylene cups: 5-year results of a randomized controlled trial.
Background and purpose - Vitamin E-infused polyethylene is a relatively new material in joint arthroplasty; there are no long-term reports, and only few mid-term results. Using radiostereometric analysis (RSA), we primarily determined whether vitamin E-infused highly cross-linked polyethylene (HXLPE/VitE) acetabular cups show less wear than ultra-high molecular weight polyethylene (UHMWPE) acetabular cups at 5 years after total hip arthroplasty (THA). We also assessed whether wear rates correlate with increasing cup inclination angles or cup sizes. ⋯ Finally, no osteolysis and implant loosening occurred, and no revision surgeries were required. Interpretation - Wear rates continue to be lower in HXLPE/VitE cups than in UHMWPE cups at 5 years of follow-up without correlation with increasing cup inclination angles or cup sizes. Finally, HXLPE/VitE cups may have the potential to prevent osteolysis and implant loosening.
-
Background and purpose - Dislocation is one of the most frequent reasons for cup revision after total hip arthroplasty (THA) for an acute fracture. A dual mobility cup (DMC) might reduce this risk. We determined the cup revision rate after THA for an acute fracture according to type of cup. ⋯ Multivariable Cox regression analyses showed lower risk of cup revision in DMC THA (n = 1,122) compared with UC THA with 22-28 mm femoral head size (n = 2,727) (HR = 0.4; CI 0.2-0.8). Interpretation - The 5-year cup cumulative incidence of revision after THA for acute fracture was comparable for DMC and UC THA. However, DMC THA had a lower risk of cup revision than UC THA with 22-28 mm femoral head.
-
Background and purpose - Virtual reality simulation of hip fracture surgery is available for orthopedic residents nationwide in Denmark. Summative assessment of learning applying the learning curve cumulative summation test (LC-CUSUM) has not been utilized in orthopedic simulation training. The strength of the LC-CUSUM is that it assumes incompetency and signals competency based on solid statistics. ⋯ Interpretation - LC-CUSUM and its summative pass/fail assessment of each simulation was feasible in this formative simulation program. Clinical educators can be reassured that participants passing HipSim are likely to continue to 2nd-5th year of residency, while failing HipSim should raise concerns and trigger career counselling and clinical supervision. The motivational aspect of LC-CUSUM pass/fail assessment when designing formative simulation training warrants further research.
-
Background and purpose - Hip precautions limiting flexion, adduction, and internal rotation have been prescribed traditionally to minimize dislocation rates following THA. We assessed the prevalence of hip dislocation following posterior approach total hip arthroplasty without postoperative hip precautions. Methods - A systematic review of multiple medical databases was performed using the PRISMA guidelines and checklist. ⋯ All but 1 study demonstrated no statistically significant differences in patient-reported outcome scores between restricted and unrestricted groups, including those pertaining to return to function, confidence, and pain. Interpretation - The review found no impact on dislocation rates following total hip arthroplasty performed through a posterior approach, regardless of the use of hip precautions. We also found no impact of the prescription of hip precautions on patient-reported outcome scores.