Translational research : the journal of laboratory and clinical medicine
-
Multicenter Study Comparative Study
Comparison of proteomic methods in evaluating biomarker-AKI associations in cardiac surgery patients.
Although immunoassays are the most widely used protein measurement method, aptamer-based methods such as the SomaScan platform can quantify up to 7000 proteins per biosample, creating new opportunities for unbiased discovery. However, there is limited research comparing the consistency of biomarker-disease associations between immunoassay and aptamer-based platforms. In a substudy of the TRIBE-AKI cohort, preoperative and postoperative plasma samples from 294 patients with previous immunoassay measurements were analyzed using the SomaScan platform. ⋯ All biomarker-AKI odds ratios were significantly different (P < 0.05) between platforms in 14% of aptamer-immunoassay pairs, none of which had high (rs > 0.50) inter-platform correlations. Although similar biomarker-disease associations were observed overall, biomarkers with high physiological concentrations tended to have the highest-confidence inter-platform operability in correlations and biomarker-disease associations. Aptamer assays provide excellent precision and an unprecedented coverage and promise for disease associations but interpretation of results should keep in mind a broad range of correlations with immunoassays.