The Journal of hand surgery, European volume
-
J Hand Surg Eur Vol · Oct 2016
Clinical results of releasing the entire A2 pulley after flexor tendon repair in zone 2C.
We report the results of complete release of the entire A2 pulley after zone 2C flexor tendon repair followed by early postoperative active mobilization in seven fingers and their comparisons with 33 fingers with partial A2 pulley release. In seven fingers, release of the entire A2 pulley was necessary to allow free gliding of the repairs in five fingers and complete release of both the A2 and C1 pulleys was necessary in two. No bowstringing was clinically evident in any finger. Two fingers required tenolysis. Using Tang's criteria, the function of two digits was ranked as excellent, four good and one fair; there was no failure. The functional return in these seven fingers was similar with that in 33 fingers with partial A2 pulley release; in these patients only one finger required tenolysis. Our results support the suggestion that release of the entire A2 pulley together with the adjacent C1 pulley does not clinically affect finger motion or cause tendon bowstringing, provided that the other pulleys are left intact. ⋯ IV.
-
J Hand Surg Eur Vol · Oct 2016
Distal transfers as a primary treatment in obstetric brachial plexus palsy: a series of 20 cases.
The purpose of this study was to examine the results of spinal accessory nerve to suprascapular nerve (with or without axillary nerve neurotization) and an Oberlin transfer as primary treatment in children with Narakas type I obstetric brachial plexus injuries, when parents refused to consent to conventional nerve trunk-/root-level reconstruction. A total of 20 children with poor shoulder abduction and no biceps antigravity function but with good hand function were treated with spinal accessory nerve to suprascapular nerve and an Oberlin transfer at a mean age of 5.8 months (SD 3.27; range 3-12.) All the patients were evaluated at a mean of 2.8 years (SD 0.8; range 1.5 to 3.8) post-operatively. Three patients were lost to follow-up. Of the remainder, 11 had grade 4+ power of elbow flexion and six patients had grade 4 power at 1 year follow-up; all had 4+ power of elbow flexion at final follow-up. At final follow-up the Mallet score was a mean of 15; (SD 4.22, range 9 to 20). Primary distal nerve transfers can give good outcomes in patients with obstetric brachial plexus injuries and may be an alternative to surgery on the nerve trunks ⋯ IV.
-
J Hand Surg Eur Vol · Jul 2016
Controlled Clinical TrialInter- and intra-tester reliability of sensibility testing in digital nerve repair.
The aim of this study was to investigate the inter- and intra-tester reliability of the static two-point discrimination and Semmes-Weinstein monofilament tests in digital nerve repair. A total of 100 digital nerves from 67 patients were included into the study. ⋯ These tests should not be used alone in the quantitative monitoring of sensory recovery, but should be interpreted with the clinical findings. Level 3 non-randomized controlled study.
-
J Hand Surg Eur Vol · Jun 2016
Meta AnalysisIs intramedullary nailing better than the use of volar locking plates for fractures of the distal radius? A meta-analysis of randomized controlled trials.
We conducted a meta-analysis of randomized controlled trials that compared the use of intramedullary nails and volar locking plates in distal radial fractures. PubMed, EMBASE and the Cochrane Collaboration Central database were used to find randomized controlled trials that met the eligibility criteria. Two reviewers screened the studies, extracted the data, evaluated the methodological quality and analysed the data with RevMan 5.1 software. No statistically significant differences were detected in the disability of the arm, shoulder and hand and the Gartland and Werley scores, radiographic parameters, wrist range of motion, grip strength, total complication rate and incidence of tendon rupture between the two groups. However, carpal tunnel syndrome occurred less often after intramedullary nailing. The two fixation methods achieved equal clinical, functional and radiological outcomes for primary fixation of the indicated types of distal radial fractures. ⋯ Therapeutic/LevelI.
-
J Hand Surg Eur Vol · Mar 2016
Comparative StudyMeasurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy.
This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. ⋯ The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy.