Injury
-
Multicenter Study
The new proximal femoral nail antirotation (PFNA) in daily practice: results of a multicentre clinical study.
The treatment of unstable trochanteric femoral fractures is still challenging. The ideal implant should be easy to handle, allow for immediate full weight-bearing postoperatively and should have sufficient purchase in the femoral head/neck-fragment to limit cut-outs due to varus-deviation and rotation. The proximal femoral nail antirotation (PFNA), designed by AO, is an intramedullary device with a helical blade rather than a screw for better purchase in the femoral head and was tested in a clinical study. ⋯ Fifty-six percent of the patients regained the pre-trauma mobility and 18% died within the follow-up period. Forty-six implant-related complications--leading to 28 unplanned re-operations--were recorded, with four acetabular penetrations (three of which were after a new fall on that hip) and seven ipsilateral femoral shaft fractures as the most serious ones. As the joint-penetrations did not resemble the cut-out seen with other implants it is concluded that the PFNA--due to its helical blade--possibly limits the effects of early rotation of the head/neck-fragment in unstable trochanteric fractures and therefore seems currently to be the optimal implant for the treatment of these fractures especially in osteoporotic bone.