Injury
-
Randomized Controlled Trial Comparative Study
Treatment of intertrochanteric fractures in elderly highrisk patients: Dynamic hip screw vs. external fixation.
Although the use of a dynamic hip screw (DHS) is considered to be the preferred treatment for intertrochanteric fractures, the external fixation device could produce clinical outcomes comparable to the outcomes obtained with conventional treatment. Furthermore, because external fixation is minimally invasive, we expected a lower rate of morbidity. Therefore, we compared the two treatments in a clinical trial of elderly patients with intertrochanteric fracture. ⋯ Treatment with external fixator is an effective treatment for intertrochanteric fractures in elderly highrisk patients. The advantages include quick and simple application, minimal blood loss, less radiation exposure, adequate fixation, pain reduction, early discharge from hospital, low costs and favourable functional outcomes.