This study was designed to assess whether intermittent impedance of inspiratory gas exchange improves the efficiency of standard cardiopulmonary resuscitation (CPR). ⋯ Intermittent impedance to inspiratory flow of respiratory gases during standard CPR significantly improves CPR efficiency during ventricular fibrillation. These studies underscore the importance of lowering intrathoracic pressures during the relaxation phase of CPR.
-
Randomized Controlled Trial Clinical Trial
Failure of splanchnic resuscitation in the acutely injured trauma patient correlates with multiple organ system failure and length of stay in the ICU.
The purpose of our study was to evaluate the relationship between the state of splanchnic perfusion and morbidity and mortality in the hemodynamically unstable trauma patient acutely resuscitated in the ICU. ⋯ Attainment of a pHi > or = 7.32 at hour 24 carried a significantly reduced likelihood of MOSF. Being an inference of the state of regional perfusion, in a high-risk microvascular bed, gastric intraluminal tonometry should identify perfusion states of compensated or uncompensated shock during hemodynamic resuscitation of the critically ill injury patient. A low pHi appears to be a marker of postresuscitative morbidity and subsequent increased length of stay.
-
Randomized Controlled Trial Clinical Trial
Effect of high-frequency oral airway and chest wall oscillation and conventional chest physical therapy on expectoration in patients with stable cystic fibrosis.
To compare the effect of high-frequency oral airway oscillation, high-frequency chest wall oscillation, and conventional chest physical therapy (CPT) on weight of expectorated sputum, pulmonary function, and oxygen saturation in outpatients with stable cystic fibrosis (CF). ⋯ In outpatients with stable CF, high-frequency oscillation applied via the airway opening or via the chest wall and CPT have comparable augmenting effects on expectorated sputum weight without changing PFTs or oxygen saturation. In contrast to CPT, high-frequency oral airway and chest wall oscillations are self-administered, thereby containing health-care expenses.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Lung deposition of fenoterol and flunisolide delivered using a novel device for inhaled medicines: comparison of RESPIMAT with conventional metered-dose inhalers with and without spacer devices.
To compare lung deposition of fenoterol or flunisolide administered from a novel, multidose inhalation device delivering liquid droplets (RESPIMAT; Boehringer Ingelheim Ltd; Bracknell, UK) or from conventional metered-dose inhalers (MDIs) with and without spacers. ⋯ The RESPIMAT device may prove to be an effective alternative to MDIs for the administration of inhaled bronchodilators and corticosteroids. The high lung deposition and low oropharyngeal deposition may lead to improved efficacy and tolerability of inhaled medications, especially corticosteroids.
-
Sepsis is the leading cause of death in the noncardiologic ICU. Maldistributed nutritive blood flow and altered convective and diffusive oxygen transport during sepsis can lead to organ dysfunction and multiple organ failure. One of the causes of myocardial dysfunction is thought to be myocardial ischemia in sepsis; however, conventional biochemical parameters to detect myocardial ischemia lack sensitivity and specificity. Serum cardiac troponin T (S-TnT) was reported to have higher sensitivity and specificity in diagnosing minor myocardial injury. The aim of this study was to investigate if and how often S-TnT is pathologically elevated in patients with sepsis and to evaluate whether S-TnT might be a prognostic marker in early sepsis. ⋯ As high S-TnT values were associated with an increased mortality rate, it seems reasonable to further evaluate S-TnT as a prognostic marker of myocardial ischemia in patients with sepsis under different therapeutic regimens.