The bone & joint journal
-
The bone & joint journal · Aug 2015
Multicenter StudyThe accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.
We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. ⋯ The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location.
-
The bone & joint journal · Aug 2015
Randomized Controlled Trial Multicenter Study Comparative StudyCost effectiveness of treatment with percutaneous Kirschner wires versus volar locking plate for adult patients with a dorsally displaced fracture of the distal radius: analysis from the DRAFFT trial.
We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius. The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care. ⋯ Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30,000. Compared with locking-plate fixation, K-wire fixation is a 'cost saving' intervention, with similar health benefits.