Anesthesiology
-
Comparative Study
Preparation of anesthesia machines for patients susceptible to malignant hyperthermia.
Malignant hyperthermia is a potentially lethal syndrome that can be triggered by inhaled anesthetics. Thus, it may be appropriate to utilize equipment that minimizes exposure of susceptible patients to inhaled anesthetics. The rate of release of anesthetic stored in anesthesia delivery systems is unknown. ⋯ Isoflurane washed out 3-4 times faster than halothane. Residual halothane concentration was approximately equal to tenfold greater when the fresh gas flow was 1 l/min rather than 10 l/min: 194 versus 19 ppm after 1 h of washout. Using a 10-l/min fresh gas flow, halothane concentrations in samples obtained from the Y-piece were similar with original or fresh soda lime but were more than tenfold lower after the fresh gas outlet hose and circle system were replaced (approximately equal to 50 ppm vs. approximately equal to 5 ppm after 5 min of washout).(ABSTRACT TRUNCATED AT 250 WORDS)
-
Comparative Study
I653 and isoflurane produce similar dose-related changes in the electroencephalogram of pigs.
I653 is a new volatile anesthetic structurally similar to enflurane and isoflurane. Since enflurane can induce convulsions, whereas isoflurane progressively depresses cortical electrical activity, the authors believed it important to assess the effect of I653 on the EEG (in both the "time" and "frequency" domain). The EEG was assessed visually and quantitatively, and a new EEG parameter was introduced. ⋯ At equipotent concentrations, I653 and isoflurane had the same effect on EEG parameters. Increasing doses of either I653 or isoflurane caused decreasing amplitude and frequency and increasing suppression. Hypocapnea during either agent slightly increased high-frequency activity, and slightly decreased burst suppression.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Intrathecal morphine reduces the minimum alveolar concentration of halothane in humans.
The authors hypothesized that the analgesia provided by intraspinal opiates would decrease anesthetic requirement. To test this hypothesis, 20 women undergoing major gynecologic surgery were divided randomly into two groups. ⋯ MAC for halothane was 0.81% in the control group and 0.46% in the intrathecal morphine group (P = 0.024). The reduction in anesthetic requirement due to intrathecal morphine is greater than that produced by low to moderate doses of systemically administered opiates.