Anesthesiology
-
The negative-pressure test using a self-inflating bulb (SIB) during emergency intubation was studied to determine its reliability and predictive value in this setting. ⋯ The SIB proved to be a sensitive and specific test for esophageal intubation in the emergency setting when used according to the protocol described, and it is complementary to carbon dioxide detection. The predictive value of the bulb syringe appears to be improved when a prolonged period for reinflation is allowed. It holds particular promise because of its low cost and portability.
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
The concordance of intraoperative left ventricular wall-motion abnormalities and electrocardiographic S-T segment changes: association with outcome after coronary revascularization. Multicenter Study of Perioperative Ischemia (McSPI) Research Group.
Transesophageal echocardiography (TEE) and Holter electrocardiography (ECG) are used to detect intraoperative ischemia during coronary artery bypass graft surgery (CABG). Concordance of these modalities and sensitivity as indicators of adverse perioperative cardiac outcomes are poorly defined. The authors tried to determine whether routine use of Holter ECG and TEE in patients with CABGs has clinical value in identifying those patients in whom myocardial infarction (MI) is likely to develop. ⋯ Wall-motion abnormalities detected by TEE are more common than S-T segment changes detected by ECG, and concordance between the two modalities is low. One half of patients with MI had preceding ECG or TEE ischemia. Logistic regression revealed that TEE is twice as predictive as ECG in identifying patients who have MI.
-
Randomized Controlled Trial Multicenter Study Comparative Study Clinical Trial
A randomized controlled trial comparing the cuffed oropharyngeal airway and the laryngeal mask airway in spontaneously breathing anesthetized adults.
The cuffed oropharyngeal airway (COPA), a modified Guedel airway, was compared with the laryngeal mask airway (LMA) during spontaneous breathing anesthesia. Specifically examined were ease of use, physiologic tolerance, and the frequency of problems. ⋯ Although the COPA and LMA are equivalent devices in terms of physiologic alterations and overall clinical problems associated with their use, the LMA was associated with a higher first-time insertion rate and fewer manipulations, suggesting that it is easier to use. The COPA was associated with less blood on the device and fewer sore throats, suggesting it may cause less pharyngeal trauma. Ultimately, both devices were similar in establishing a safe and effective airway for spontaneously breathing anesthetized adults.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Mood during epidural patient-controlled analgesia with morphine or fentanyl.
Mood states during epidural opioids are not known. The authors studied the change in mood during the 48-h period of epidural morphine and epidural fentanyl in 47 patients after elective hip or knee joint arthroplasty. ⋯ Mood states are significantly more positive during epidural morphine PCA than they are during epidural fentanyl PCA.