Although tests of psychomotor function indicate that drug effects after ambulatory anesthesia are short-lived, patients often feel washed out for long periods of time. Among the psychomotor tests that measure different motor and cognitive functions, none directly measures sleepiness or alertness. The authors hypothesized that sleepiness, measured by a sleep latency test, would be a more sensitive indicator of drug effect after an anesthetic than psychomotor tests. The second objective was to determine a sedation regimen that produced the least residual effect. ⋯ The multiple sleep latency test may be a more sensitive measure of a drug's effect than other tests of psychomotor function. For up to 8 h after an injection of midazolam and fentanyl, patients must consider driving or operating heavy machinery unsafe activities.
-
Preparation of anesthetic machines for use with malignant hyperthermia-susceptible (MHS) patients requires that the machines be flushed with clean fresh gas. We investigated the washout of inhalational anesthetics from the KION anesthetic machine. ⋯ To prepare the KION anesthetic machine for MHS patients, the machine without the carbon dioxide absorber must be flushed with 10 l/min FGF for at least 25 min to achieve 10 ppm anesthetic concentration. This FGF should be maintained throughout the anesthetic to avoid increases in anesthetic concentration in the FGF.
-
The aim of this study was to determine if the ischemic tolerance could be induced in the spinal cord by pretreatment with hyperbaric oxygen (HBO) and what components of HBO (hyperoxia, hyperbaricity, and combination of these two) were critical in the induction of tolerance against ischemic injury. ⋯ Serial exposure to high oxygen tension induced ischemic tolerance in spinal cord of rabbits. Simple hyperbaricity (2.5 ATA, 21% O2) did not induce ischemic tolerance.
-
Many hyperbaric facilities use infusion pumps inside the chamber. It is therefore important to ensure that this equipment will perform accurately during hyperbaric conditions. The authors tested the function and accuracy of the Imed 965 and Infutec 520 volumetric infusion pumps, the Easy-pump MZ-257 peristaltic infusion pump, and the Graseby 3100 syringe pump. ⋯ Commercially available infusion pumps operating during hyperbaric conditions demonstrate substantial variations in performance and accuracy. It is therefore important that the hyperbaric facility staff make a careful examination of such instruments to anticipate possible deviations in the accuracy of the equipment during use.
-
A model of an antegrade, perfused, isolated rat peroneal nerve anterior tibial muscle was developed to study potentially important factors governing the time course of action of (nondepolarizing) neuromuscular blocking agents such as concentration, blood flow, and temperature. The model allows observation of the effects of selective changes in these factors. ⋯ The authors developed and validated a model that allows us to study biophase kinetics of neuromuscular blocking agents in the anterior tibial muscle of the rat. In this model, muscle-blood flow rather than EC90 appears to predominantly determine the onset and offset time of nondepolarizing muscle relaxants.