Randomized Controlled Trial Comparative StudyThe temperature and humidity in a low-flow anesthesia workstation with and without a heat and moisture exchanger.
The Dräger Primus anesthesia workstation has a built-in hotplate to heat the patient's exhaled gas. The fresh gas flow is mixed with the heated exhaled gas as they pass through the soda lime canister. A heat and moisture exchanger (HME) may also be used to further heat and humidify the inhaled gas. In this study we measured the temperature and humidity of the inhaled gas coming from the Dräger Primus with or without a HME. ⋯ The Primus anesthesia workstation partially humidifies the inspired gas when a low fresh gas flow is used. Insertion of an HME increases the humidity in inhaled gas, bringing it close to physiological values.
-
Assessment of diastolic function should be a component of a comprehensive perioperative transesophageal echocardiographic examination. Abnormal diastolic function exists in >50% of patients presenting for cardiac and high-risk noncardiac surgery, and has been shown to be an independent predictor of adverse postoperative outcome. Normalcy of systolic function in 50% of patients with congestive heart failure implicates diastolic dysfunction as the probable etiology. ⋯ The availability of more sophisticated Doppler techniques, e.g., Doppler tissue imaging and flow propagation velocity, makes it possible to interrogate left ventricular diastolic function with greater precision, analyze specific stages of diastole, and to differentiate abnormalities of relaxation from compliance. Additionally, various Doppler-derived ratios can be used to estimate left ventricular filling pressures. The varying hemodynamic environment of the operating room mandates modification of the diagnostic algorithms used for ambulatory cardiac patients when left ventricular diastolic function is evaluated with transesophageal echocardiography in anesthetized surgical patients.
-
Anesthesia and analgesia · Sep 2011
Randomized Controlled TrialThe effect of altering skin-surface cooling speeds on vasoconstriction and shivering thresholds.
Both core and skin temperatures contribute to steady-state thermoregulatory control. Dynamic thermoregulatory responses trigger aggressive defenses against rapid thermal perturbations. These responses potentially complicate interpretation of thermoregulatory studies and could slow induction of therapeutic hypothermia. We thus tested the hypothesis that rapid external skin-cooling triggers vasoconstriction and shivering at higher mean skin temperatures than slow or moderate rates of skin cooling. ⋯ Onset of vasoconstriction and shivering occurred at similar mean skin temperatures with all 3 cooling rates. Aggressive surface cooling can thus be used in thermoregulatory studies and for induction of therapeutic hypothermia without provoking dynamic thermoregulatory defenses.
-
Anesthesia and analgesia · Sep 2011
Randomized Controlled TrialAn exploration of remifentanil-propofol combinations that lead to a loss of response to esophageal instrumentation, a loss of responsiveness, and/or onset of intolerable ventilatory depression.
Remifentanil and propofol are increasingly used for short-duration procedures in spontaneously breathing patients. In this setting, it is preferable to block the response to moderate stimuli while avoiding loss of responsiveness (LOR) and intolerable ventilatory depression (IVD). In this study, we explored selected effects of combinations of remifentanil-propofol effect-site concentrations (Ces) that lead to a loss of response to esophageal instrumentation (EI), LOR, and/or onset of IVD. A secondary aim was to use these observations to create response surface models for each effect measure. We hypothesized that (1) in a large percentage of volunteers, selected remifentanil and propofol Ces would allow EI but avoid LOR and IVD, and (2) the drug interaction for these effects would be synergistic. ⋯ Selected remifentanil-propofol concentration pairs, especially higher propofol-lower remifentanil concentration pairs, can block the response to EI while avoiding IVD in spontaneously breathing volunteers. It is, however, difficult to block the response to EI and avoid both LOR and IVD. It may be necessary to accept some discomfort and blunt rather than block the response to EI to consistently avoid LOR and IVD.
-
Anesthesia and analgesia · Sep 2011
Comparative Study Clinical TrialEvaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery.
Reliable cardiac output monitoring is particularly useful in the cirrhotic patient undergoing liver transplant surgery, because cirrhosis of the liver is associated with a vasodilated and high output state, known as cirrhotic cardiomyopathy, that challenges the reliability of pulse contour cardiac output technology. The contractility of the ventricle in cirrhosis is impaired, which is tolerated even though the ejection fraction and cardiac output are elevated because of the low peripheral resistance. However, during surgery the cirrhotic patient can decompensate because of the physiological changes and stress of surgery. Recently, we showed that the FloTrac/Vigileo™ failed to perform in cirrhotic patients undergoing transplant surgery. In response, the company upgraded their software. Therefore, we have assessed the accuracy and reliability of this new third-generation (version 3.02) FloTrac/Vigileo algorithm software in the same setting. ⋯ The new software (version 3.02) provided substantial improvements over the previous versions with better overall precision and trending ability. Further algorithm refinements will increase this technology's reliability to be extensively used in the highly complex setting of cirrhotic patients undergoing liver transplantation.