Anesthesia and analgesia
-
Anesthesia and analgesia · Feb 2017
Randomized Controlled Trial Comparative StudyDural Puncture Epidural Technique Improves Labor Analgesia Quality With Fewer Side Effects Compared With Epidural and Combined Spinal Epidural Techniques: A Randomized Clinical Trial.
The dural puncture epidural (DPE) technique is a modification of the combined spinal epidural (CSE) technique, where a dural perforation is created from a spinal needle but intrathecal medication administration is withheld. The DPE technique has been shown to improve caudal spread of analgesia compared with epidural (EPL) technique without the side effects observed with the CSE technique. We hypothesized that the onset of labor analgesia would follow this order: CSE > DPE > EPL techniques. ⋯ Analgesia onset was most rapid with CSE with no difference between DPE and EPL techniques. The DPE technique has improved block quality over the EPL technique with fewer maternal and fetal side effects than the CSE technique for parturients requesting early labor analgesia.
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisClinical Performance and Safety of Closed-Loop Systems: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.
Automated systems can improve the stability of controlled variables and reduce the workload in clinical practice without increasing the risks to patients. We conducted this review and meta-analysis to assess the clinical performance of closed-loop systems compared with manual control. Our primary outcome was the accuracy of closed-loop systems in comparison with manual control to maintain a given variable in a desired target range. ⋯ We observed a significant reduction of episodes of overshooting and undershooting when closed-loop systems were used. The use of automated systems can result in better control of a given target within a selected range. There was a decrease of overshooting or undershooting of a given target with closed-loop systems.
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisClosed-Loop Delivery Systems Versus Manually Controlled Administration of Total IV Anesthesia: A Meta-analysis of Randomized Clinical Trials.
Bispectral Index Scale (BIS)-guided closed-loop delivery of anesthetics has been extensively studied. We performed a meta-analysis of all the randomized clinical trials comparing efficacy and performance between BIS-guided closed-loop delivery and manually controlled administration of total IV anesthesia. Scopus, PubMed, EMBASE, and the Cochrane Central Register of clinical trials were searched for pertinent studies. ⋯ Closed-loop anesthetic delivery performed better than manual-control delivery. Both median absolute performance error and wobble index were significantly lower in closed-loop anesthetic delivery systems group (MD = 5.82 [3.17-8.46], P for effect <0.00001, P for heterogeneity <0.00001, I = 90% and MD = 0.92 [0.13-1.72], P for effect = 0.003, P for heterogeneity = 0.07, I = 45%). When compared with manual control, BIS-guided anesthetic delivery of total IV anesthesia reduces propofol requirements during induction, better maintains a target depth of anesthesia, and reduces recovery time.