Anesthesia and analgesia
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisClinical Performance and Safety of Closed-Loop Systems: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.
Automated systems can improve the stability of controlled variables and reduce the workload in clinical practice without increasing the risks to patients. We conducted this review and meta-analysis to assess the clinical performance of closed-loop systems compared with manual control. Our primary outcome was the accuracy of closed-loop systems in comparison with manual control to maintain a given variable in a desired target range. ⋯ We observed a significant reduction of episodes of overshooting and undershooting when closed-loop systems were used. The use of automated systems can result in better control of a given target within a selected range. There was a decrease of overshooting or undershooting of a given target with closed-loop systems.
-
Anesthesia and analgesia · Feb 2017
Review Meta Analysis Comparative StudyComparison of Supraclavicular and Infraclavicular Brachial Plexus Block: A Systemic Review of Randomized Controlled Trials.
Supraclavicular (SC) and infraclavicular (IC) brachial plexus block (BPB) are commonly used for upper extremity surgery. Recent clinical studies have compared the effect of SC- and IC-BPB, but there have been controversies over spread of sensory blockade in each of the 4 peripheral nerve branches of brachial plexus. ⋯ This meta-analysis demonstrated that IC-BPB showed a significantly high incidence of incomplete radial nerve sensory block at 30 minutes, which may be avoided by double or triple injection. Furthermore, IC-BPB with multiple injection technique showed significantly lower incidence of incomplete ulnar block than SC-BPB. There were no differences in the incidence of successful blockade, block onset, and duration of analgesia between SC- and IC-BPB. Procedure-related paresthesia/pain and adjacent nerve-related complications were more frequent in SC-BPB. However, because of the small sample size, publication bias remains a concern when interpreting our results. Further studies with sufficient sample size and reporting large number of outcomes are required.
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisClosed-Loop Delivery Systems Versus Manually Controlled Administration of Total IV Anesthesia: A Meta-analysis of Randomized Clinical Trials.
Bispectral Index Scale (BIS)-guided closed-loop delivery of anesthetics has been extensively studied. We performed a meta-analysis of all the randomized clinical trials comparing efficacy and performance between BIS-guided closed-loop delivery and manually controlled administration of total IV anesthesia. Scopus, PubMed, EMBASE, and the Cochrane Central Register of clinical trials were searched for pertinent studies. ⋯ Closed-loop anesthetic delivery performed better than manual-control delivery. Both median absolute performance error and wobble index were significantly lower in closed-loop anesthetic delivery systems group (MD = 5.82 [3.17-8.46], P for effect <0.00001, P for heterogeneity <0.00001, I = 90% and MD = 0.92 [0.13-1.72], P for effect = 0.003, P for heterogeneity = 0.07, I = 45%). When compared with manual control, BIS-guided anesthetic delivery of total IV anesthesia reduces propofol requirements during induction, better maintains a target depth of anesthesia, and reduces recovery time.
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisPreoxygenation: Physiologic Basis, Benefits, and Potential Risks.
Preoxygenation before anesthetic induction and tracheal intubation is a widely accepted maneuver, designed to increase the body oxygen stores and thereby delay the onset of arterial hemoglobin desaturation during apnea. Because difficulties with ventilation and intubation are unpredictable, the need for preoxygenation is desirable in all patients. During emergence from anesthesia, residual effects of anesthetics and inadequate reversal of neuromuscular blockade can lead to hypoventilation, hypoxemia, and loss of airway patency. ⋯ Absorption atelectasis is a consequence of preoxygenation. Two approaches have been proposed to reduce the absorption atelectasis during preoxygenation: a modest decrease in the fraction of inspired oxygen to 0.8, and the use of recruitment maneuvers, such as CPAP, PEEP, and/or a vital capacity maneuver (all of which are commonly performed during the administration of anesthesia). Although a slight decrease in the fraction of inspired oxygen reduces atelectasis, it does so at the expense of a reduction in the protection afforded during apnea.
-
Anesthesia and analgesia · Feb 2017
Review Meta AnalysisAnesthesia and Databases: Pediatric Cardiac Disease as a Role Model.
Large data sets have now become ubiquitous in clinical medicine; they are particularly useful in high-acuity, low-volume conditions such as congenital heart disease where data must be collected from many centers. These data fall into 2 categories: administrative data arising from hospital admissions and charges and clinical data relating to specific diseases or procedures. In congenital cardiac diseases, there are now over a dozen of these data sets or registries focusing on various elements of patient care. ⋯ In the absence of regionalization, collaborative learning techniques have consistently been shown to minimize this variability and improve care at all centers, but before changes can be made it is necessary to accurately measure accurately current patient outcomes. Outcomes measurement generally falls under hospital-based QI initiatives, but more detailed analysis and research require Institutional Review Board and administrative oversight. Cardiac anesthesia providers for these patients have partnered with the Society of Thoracic Surgeons Congenital Heart surgeons to include anesthesia elements to help in this process.