Anesthesia and analgesia
-
Anesthesia and analgesia · Dec 1996
Biphasic drug absorption from the epidural space of the dog may limit the utility of a slow release medium molecular weight hyaluronic acid-lidocaine ionic complex formulation.
Previous epidural studies conducted in rabbits have described a viscous lidocaine-hyaluronate formulation (L-HA) that prolonged the duration of sensory blockade twofold and decreased the rate of drug absorption fourfold relative to a solution formulation. As further evaluation of the L-HA formulation required studies in a larger animal that more closely reflected the characteristic absorption kinetics observed in humans, a conscious dog model was used to functionally and kinetically evaluate the viscous formulation relative to lidocaine solution. In terms of the measured pharmacodynamic end point (loss of weight-bearing ability in hind legs), epidural administration of the L-HA formulation did not prolong the duration of action relative to lidocaine solution in spite of a markedly altered pharmacokinetic profile. ⋯ The L-HA formulation markedly altered the absorption kinetics such that a single, slow absorption phase was evident (apparent t1/2 of 56 min), although this rate was more rapid than the slow phase observed after lidocaine solution. It is possible that the inability of the hyaluronate-based formulation to further reduce the magnitude of the slow absorption phase resulted in the failure to prolong the duration of action. These data highlight the need to carefully consider the absorption kinetics and pharmacokinetic characteristics of the animal models chosen to evaluate new formulation of epidurally administered local anesthetics.
-
Anesthesia and analgesia · Dec 1996
Aspirin does not increase allogeneic blood transfusion in reoperative coronary artery surgery.
While preoperative aspirin (ASA) therapy does not increase allogeneic transfusion in elective primary coronary artery bypass grafting (CABG) operations, the impact of ASA consumption on transfusion in cardiac operations with greater risk of bleeding has not been investigated. We examined the influence of ASA consumption on mediastinal drainage and allogenic transfusion in 317 patients undergoing reoperative CABG surgery. Patients receiving ASA or ASA containing medications within 7 days preoperatively (n = 215) had similar perioperative characteristics but were older and had smaller red cell volumes than control patients not receiving ASA (n = 102). ⋯ Logistic regression demonstrated that female gender, prolonged duration of CPB, advanced age, use of IABP, and a negative history of smoking were significant independent predictors of blood product transfusion. There was no significant interaction of preoperative heparin therapy with ASA on transfusion demonstrated by univariate or multivariate analyses. These results indicate that preoperative ASA ingestion is not an important determinant of mediastinal drainage or allogeneic transfusion, even after repeat CABG operations, and that surgical and patient characteristics are more important predictors of these outcomes.
-
Anesthesia and analgesia · Dec 1996
Comparative StudyDelayed time response of the continuous cardiac output pulmonary artery catheter.
Previous studies of the accuracy of pulmonary artery catheters (PAC) which provide continuous cardiac output (CCO) monitoring have investigated the performance during steady-state conditions. We compared the response time to hemodynamic change using a CCO PAC and an ultrasonic flow probe (UFP). In five sheep, a CCO PAC was inserted, and an UFP for measurement of CCO was placed around the pulmonary artery via a left thoracotomy. ⋯ The time interval for 80% change was 14.5 +/- 4.1 min for CCO versus 1.8 +/- 0.9 min with UFP. The current study demonstrates clinically important time delays in the response of the CCO catheter. This delay must be considered when rapid alterations of the hemodynamic state may occur.
-
Anesthesia and analgesia · Dec 1996
Comparative StudyTransesophageal echocardiography: an objective tool in defining maximum ventricular response to intravenous fluid therapy.
Ventricular preload is an important determinant of cardiac function, which is indirectly measured in the clinical setting by the pulmonary capillary wedge pressure (PCWP). Transesophageal echocardiography (TEE) is rapidly gaining acceptance as a monitor of cardiac function. Although it provides high-resolution images of cardiac structures, clinical assessment of ventricular preload using TEE has been subjective, since quantitative measurements have been difficult to perform in a timely fashion. ⋯ Similar analysis comparing PCWP to changes in CO and LVSW failed to demonstrate a significant relationship (P = 0.54 and P = 0.36, respectively). These data suggest that changes in EDA measured using TEE with ABD are related to trends in cardiac function and can suggest an appropriate end point for intravenous fluid administration as defined by maximum CO and LVSW. PCWP did not demonstrate a significant relationship to changes in CO and LVSW.