The Annals of thoracic surgery
-
Conservation and autotransfusion of autologous blood have been proposed as a means to decrease the homologous blood requirements of cardiac surgery. Use of the Haemonetics Cell Saver System to salvage blood shed in the sterile surgical field resulted in a net saving of 105 +/- 88.7 ml of packed red cells in 20 patients undergoing cardiopulmonary bypass. The system is not a cost-effective way to save blood or decrease homologous blood requirements during routine cardiac operations.
-
Comparative Study
Circulatory dynamics during surface-induced hypothermia under halothane-ether azeotrope anesthesia.
Circulatory dynamics during surface- induced deep hypothermia using the halothane-diethyl ether azeotrope in 100% oxygen (O2) without circulatory arrest and 95% O2 and 5% carbon dioxide (CO2) with and without 60 minutes of arrest were evaluated in 15 adult mongrel dogs. Mean arterial pressure was lower in animals given 5% CO2 than in animals given 100% O2 during cooling. Cardiac output in the 5% CO2 groups increased until 30 degrees C cooling and then gradually decreased to 29% of control at 20 degrees C. ⋯ Hemodynamic variables in animals given 5% CO2 did not reveal significant differences in arrested versus nonarrested animals during early rewarming. However, with further warming, cardiac output, stroke volume, left ventricular stroke work, and mean pulmonary arterial and pulmonary artery wedge pressures were lower, and systemic and pulmonary vascular resistances were higher in the arrest group. We conclude that the improved results with halothane-diethyl ether azeotrope in 95% O2 and 5% CO2 during surface hypothermia are due to a greater cardiac output and reduced peripheral vascular resistance.
-
We present the case of a patient who had rupture of a pulsatile assist device (PAD) accompanied by massive air embolism, and the treatment that brought it to a successful outcome. After rupture of the skin of the PAD balloon, a massive amount of air was injected into the ascending aorta. ⋯ After completion of the operation, the patient was partially rewarmed to 30 degrees C central temperature and transported by ambulance to a hyperbaric chamber where he was compressed to 6 atmospheres absolute 9 hours after the accident with clinical signs of severe brain dysfunction. The patient recovered completely and was discharged from the hospital on the tenth postoperative day.
-
Two patients experienced an episode of massive air embolism during extracorporeal circulation. Several emergency measures were taken. (1) The roller pump was reversed to take out air from the aorta. (2) The circuit was disconnected and recirculated to eliminate air bubbles. (3) Perfusion was restarted and the patient cooled to 24 degrees C for 40 minutes. (4) Pentothal (thiopental), steroids, and assisted ventilation were administered. The outcome was favorable in both patients, and there were no neurological sequelae. Immediate cooling and prolonged circulation seem to be a satisfactory approach to this problem.